Pulsed Flame Photometric Detector (PFPD)

PriceRequest Pricing

SKU330713


Superior selectivity and sensitivity for easy analysis of sulfur, phosphorus, and 26 other elements.

  • Overview

    Be Selective With Your Data

    Our 5383 Pulsed Flame Photometric Detector (PFPD) is linear, with an equimolar response to sulfur permitting selective measurement of individual sulfur species from low ppb to ppm levels and total sulfur as the sum of individual peaks. The unique capability to obtain simultaneous sulfur and hydrocarbon chromatograms from a single detector sets it apart from other sulfur detection technologies.

    Widely used in laboratory and process gas chromatographs to analyze sulfur species and total sulfur levels in liquid-phase petrochemicals, you will also find the Model 5383 hard at work analyzing organophosphorus pesticides, pharmaceuticals, flavor, and fragrances, beverage-grade CO2, chemical warfare agents, and more.

    Designed for a Variety of Applications

    Compact and modular, the new, second-generation 5383 Pulsed Flame Photometric GC Detector offers greater ease of use, design flexibility, and analytical refinement than its predecessor, while retaining the proven technology features that laboratories around the world rely on for accurate results.

    The 5383 PFPD is a great instrument if you're monitoring any of the following: Sulfur in petrochemicals, organophosphorus pesticides, flavor and fragrance analyses, Sulfur in beverage-grade CO2, simultaneous PFPD and MS detection, chemical warfare agents, Organotin compounds & Organometallic detection, explosives analysis P, S, As, Si detection (semiconductors), or Sulfur in pharmaceuticals. 

    Capabilities

    • Superior sensitivity and increased selectivity for S and P compared to conventional FPDs
    • Linear, equimolar response for quick, easy calibrations
    • Simultaneous mutually selective chromatograms (e.g., S+C, or S+P) • Self-cleaning design eliminates soot formation, or “coking,” seen in other sulfur-selective detectors
    • Modular design with separate electronics and flow modules
    • Better long-term stability and less maintenance than other S-selective detectors, such as SCD/XRF

    With a significant improvement in signal processing and a 10-fold increase in sensitivity over most traditional FPDs, the detector makes accurate analysis of sulfur, phosphorus, and other elements easier than ever before. The intuitive, easy-to-use software suite with integrated monitoring and analysis capabilities provides a powerful tool for parameter optimization, data analysis, and more. Reliable and cost-effective, the 5383 uses significantly less gas than SCDs or FPDs and requires considerably less maintenance. 

  • Specifications
    Detectivity  
    ​​Sulfur <1 pg S/sec
    Phosphorus <100 fg P/sec

     

    Sensitivity   
    Sulfur Signal-to-Noise >300 (at 10 pg S/sec elution rate peakto-peak noise)
    Drift (S or P) <10x peak-to-peak noise in 20 min

    Selectivity (at Optimum Detectivity Levels)  
    Sulfur >106 S/C
    Phosphorus > 105 P/C (selectivity is adjustable with a trade-off in detectivity)
    Detector Linearity  
    Sulfur Quadratic in response. Linear to approximately 2.4 orders of magnitude. Detector (nonlinear) dynamic range ~3 orders of magnitude.
    Phosphorus First order linear over approximately 5 orders of magnitude.
    Response Uniformity​ Equimolor ±8% (S, P)
    Chromatographic Peak Tailing <0.2 sec in S and P

     

    Gas Requirements  
    Carrier He or H2 at 40 psig; 99.8% purity or better
    Air 40 psig; zero air (CGA grade E)
    Hydrogen​ 40 psig; 99.995% purity or better (electrolytic grade)
    Power Requirements 115/230 VAC

     

    Computer Requirements  
    Operating System Windows® 7, 8 and 10
    Communication Ports USB (1)
    Minimum Temperature  180 °C
    Maximum Temperature 420 °C
    Carrier Gas 5 mL/min maximum flow rate helium; up to 10 mL/min using H2 carrier gas

     

    Typical Gas Consumption  
    H2 10–15 mL/min
    Air 20–30 mL/min
    Humidity​ 5–80% relative humidity
    Altitude 2,000 m maximum

     

    Safety/EMI Certifications  
    RoHS Directive 2011/65/EU
    EMC Directive 2004/108/EC
    EN 61326-1:2013
    CISPR 11:2009 and A1:2010
    Safety​ LVD 2006/95/EC
    EN 61010-1:2010 3rd

     

    Controller Board Inputs and Outputs  
    Two Channels (to GC) 0-1 V
    One Serial RS-485
    One Signal In​ Electrometer; PFPD
    High Voltage Out PMT 0-1,000 V
    Ignitor Current 0-3.4 A
    S/W HV Protection PMT Protection
    Timed Events (from GC Remote Start) Autozero, range, attenuation, ignitor, mode or channel (e.g. S, P, C), and record
    Controller Dimensions 17.5 cm H x 6 cm W x 25 cm D
    (6.9" H x 2.4" W x 9.9" D)
    Pneumatics Module Dimensions 17.5 cm H x 6 cm W x 27.5 cm D
    (6.9" H x 2.4" W x 10.3" H)
    Pneumatic Control  EPC-Ready Control utilizes GC electronic flow control of detector gases or manual flow control of detector gases with mass flow controllers and metering valve
  • Accessories

You may also need

4760 Eclipse Purge and Trap Sample Concentrator

Eclipse Purge and Trap Concentrator

Request Pricing

5360 XSD™ Halogen Selective Detector

GC Detector

Request Pricing

Photoionization Detectors (PID)

GC Detector

Request Pricing

4551A Purge and Trap Autosampler

Purge-and-Trap Water Autosampler

Request Pricing