5350 Tandem PID/ELCD

PriceRequest Pricing

SKU325249


Increase efficiency and save counter space with the Model 5350 Tandem Photoionization Detector/Electrolytic Conductivity Detector (PID/ELCD), a smartly designed instrument for dual detection of aromatic and halogen compounds.

  • Overview

    The Model 5350 Tandem PID/ELCD packs in the power of two great detectors: Model 4430 PID and Model 5320 ELCD, removing the need for separate analyses of aromatic and halogen compounds. Its unique design eliminates transfer lines and uses only one detector port. Detectors can be used separately if desired. The 5350 Tandem PID/ELCD is compatible with most GC manufacturer’s instruments.

    Model 5350 Tandem PID/ELCD Features:

    • Unique tandem design eliminates transfer lines and minimizes dead volume
    • Tandem detector design uses only one GC detector port
    • Patented UV Lamp Window Sweep™ design minimizes fouling from window surface contamination
    • Exclusive Lampsaver™ circuit can be programmed to turn PID lamp off after a specified period to improve lamp life
    • ELCD incorporates quick change, disposable deionizing resin cartridge, and a simplified solvent system
    • Reactor design uses brass and graphite/Vespel® ferrules instead of solid graphite ferrules
    • Programmable solvent venting through GC timed event

  • Specifications
    4430 PID Specifications  
    Dynamic Range > 106
    Linear Range > 106
    ​Sensitivity​ > 40 pg Benzene
    Maximum Operating Temperature 250 ˚C
    Lamp Current 0–1.60 mA (in 9 steps)
    Lampsaver Time 0.5–2 hr, reset by external contact
    Patent The 4430 PID is protected under U.S. Patent number 4,804,846.
    Gas Requirements Helium (99.999%)
    Lamp Power Supply Power Requirements 105–240 VAC (±10%)
    47–63 Hz
    Lamp Power Supply Weight 2.5 kg (5.5 lb)
    Lamp Power Supply Dimensions 5.75” H x 2.75” W x 9.0” D

     

    5320 ELCD Specifications - Halogen Mode  
    Detectable Mass  
    Maximum*​  1 pg lindane
    Maximum 5 µg lindane
    Dynamic Range 5 x 106
    Selectivity Cl/HC > 106
    Cl/N > 105
    Cl/S > 105
    Reactor Temperature  
    Range 800 – 1,100 ˚C in 100 ˚C increments
    Stability ± 1 ˚C
    Solvent Flow Adjustable on the cell amplication board
    Solvent Flow Range 0-200 µL/min
    Solvent Vent Valve Controlled by GC-timed event relay
    Gas Requirements H2 (99.999%) Halogen Mode
    Detector Controller Power Requirements 90–260 VAC (±10%)
    47-63 Hz, 200W
    Detector Controller Weight 3.8 kg (8.4 lb)
    Detector Controller Dimensions 8.25” H x 5.0” W x 12” D
  • Accessories

You may also need

Pulsed Flame Photometric Detector (PFPD)

Pulsed Flame Photometric Detector

Request Pricing

5320 ELCD | Electrolytic Conductivity Detector

Electrolytic Conductivity Detector (ELCD)

Request Pricing

4760 Eclipse Purge and Trap Sample Concentrator

Eclipse Purge and Trap Concentrator

Request Pricing

Photoionization Detectors (PID)

GC Detector

Request Pricing

5360 XSD™ Halogen Selective Detector

GC Detector

Request Pricing