3017M DPD Chlorine Analyzer

Chlorine Measurement:

DPD vs Amperometric

3017M FAQ

PriceRequest Pricing

Option

SKU330001


Accurate, reliable chlorine analysis from a brand you trust.

The 3017M Chlorine Analyzer is YSI’s newest online analyzer! This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA approved method. To learn more about how the 3017M can be used in other applications click below.

What’s Included:

  • (330001) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30 day supply (at a 2.5-minute measurement interval) of total chlorine reagent and buffer solution
  • (330002) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30 day supply (at a 2.5-minute measurement interval) of free chlorine reagent and buffer solution
  • (330003) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30 day supply (at a 2.5-minute measurement interval) of total chlorine reagent and buffer solution; Sample Inlet Device
  • (330004) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30 day supply (at a 2.5-minute measurement interval) of free chlorine reagent and buffer solution; Sample Inlet Device

  • Overview

    The YSI 3017M Chlorine Analyzer uses proven DPD methodology to provide accurate and reliable free chlorine or total chlorine measurements in drinking water and final effluent wastewater samples. The 3017M can also be used in aquatic habitats and industrial cooling tower applications.

    The 3017M is simple and low maintenance, with Flow Injection Analysis (FIA), factory calibration, and simplified tubing. Low reagent use reduces maintenance frequency. The analyzer can operate as a standalone unit or be integrated into YSI’s IQ SensorNet system of online controllers, analyzers, and sensors for better visibility and control of your process.

    The 3017M’s reliability and low-maintenance design ensure the collection of reliable data with minimal effort.

    • Accurate and reliable - Measures free or total chlorine in drinking water or municipal wastewater final effluent using the DPD colorimetric method. This highly accurate method of analysis provides reliable data for process optimization and reporting.
    • Low maintenance – Flow Injection Analysis (FIA) simplifies maintenance and saves you time. Simplified tubing and low reagent use reduce the frequency of instrument maintenance.
    • EPA & ISO compliant – The 3017M is compliant with US EPA regulations 40 CFR 141.74 (drinking water) and 40 CFR 136.3 (wastewater) and the 3017M measurement method conforms with standard method 4500-CL-G and US EPA method 334.0, which makes it suitable for drinking water permit reporting in the United States. In addition, the 3017M measurement method conforms with ISO method 7393-2.
    • Factory calibrated – Eliminates the need for regular calibration.

    Primary applications include:

    • Monitoring residual chlorine in drinking water for process optimization, alarming, and reporting.
    • Disinfection control, monitoring dechlorination, and process optimization in wastewater.

    Secondary applications include:

    • Monitoring chlorine levels in cooling towers to control corrosion and slime/algae build-up.
    • Monitoring chlorine levels in aquaculture and aquatic habitats to protect aquatic ecosystems.

  • Specifications
    Performance  
    Measurement Method
    N, N-Diethyl-p-phenylenediamine (DPD)
    Measurement Range 0-5 mg/L free or total chlorine, reagent dependent
    Measurement Interval Programmable; 2.5 to 60 minutes
    Accuracy ±0.03 mg/L or ±5%, whichever is greater
    Limit of Detection 0.03 mg/L
    Calibration Factory calibrated, 1-point if required
    Resolution 0.01 mg/L
    General  
    Display 2.8 x 6 cm backlit LCD
    Enclosure IP66 (with door latched)
    Instrument Dimensions 16.8 x 14.8 x 7.4 inches (42.7 x 37.6 x 18.8 cm)
    Mounting 4 mounting struts bolted to back of unit
    Instrument Shipping Weight <18 lbs ; 8 kg
    Warranty 2 year warranty
    Regulatory Compliance US EPA regulations 40 CFR 141.74 and 40 CFR 136.3; Standard method
    4500-CL-G; US EPA method 334.0; ISO method 7393-2
    Certification CE, cETLus
    Language English, French, German, Italian, Spanish
    Sample Requirements  
    Sample Flow Rate to Sample Inlet Device 50 to 1,000 mL/min when using Sample Inlet Device
    Inlet Pressure 1 to 20 psig with Sample Inlet Device
    Sample Temperature Range 41 to 113 °F (5 to 45 °C)
    Reagents and Requirements  
    Reagent Sets 330006 - Reagent set for measuring total chlorine; includes total chlorine
    indicator, total chlorine buffer, and DPD powder
    330007 - Reagent set for measuring free chlorine; includes total chlorine
    indicator, total chlorine buffer, and DPD powder
    Reagent Consumption ~30 days per bottle at at 2.5 minute measurement interval
    Reagent Storage Life (before hydration) Buffer and indicator, 5 years
    DPD powder , 1 year
    Reagent Bottle Volume (after hydration) 0.5 liter
    Power and Communication  
    Power 115-230 VAC , 50-60 Hz, 70VA
    Relays Two relays rated at 6A, 30VDC
    Analog Output One 4-20 mA configurable output
    Digital Output RS-485 Modbus RTU
    Optical  
    Light Source Class 1 LED; wavelength centered at 525 nm
    Light Path Length >1 cm
    Environmental  
    Storage Temperature Range 41 to 158 °F (5 to 70 °C)
    Operating Temperature Range 41 to 131 °F (5 to 55 °C)
    Relative Humidity 90% at 40°C non-condensing
  • Accessories

    3017M Tubing Set

    Replacement tubing set for 3017M

    Sample Inlet Device

    Sample Inlet Device for 3017M

    Reagent Caps

    Reagent caps for the 3017M reagent bottles

    Silicone Lubricant

    Silicone lubricant for the 3017M sample pump tube

You may also need

IQ SensorNet 2020 3G Controller

Modular water quality monitoring system for a complete sensor network that measures up to 20 parameters

Request Pricing

IQ SensorNet 282/284 Controller

Modular system for a complete sensor network ideal for various installation needs

Request Pricing

IQ SensorNet Analog Input Module

Analog input module that integrates third-party sensors and analyzers into the IQ SensorNet Network.

Request Pricing

3017M Tubing Set

Replacement tubing set for 3017M

$125.00

Sample Inlet Device

Sample Inlet Device for 3017M

Request Pricing

Replacement Filter for Sample Inlet Device

Replacement filter

Request Pricing