3017M DPD Chlorine Analyzer

Chlorine Measurement:

DPD vs Amperometric

3017M FAQ

PriceRequest Pricing

Option

SKU330003


Accurate, reliable chlorine analysis from a brand you trust.

The 3017M Chlorine Analyzer is YSI’s newest online analyzer! This DPD colorimetric analyzer is used for continuous measurements of free or total chlorine in municipal drinking water and wastewater applications using an EPA-approved method. To learn more about how the 3017M can be used in other applications, click below.

What’s Included:

  • (330003) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30-day supply (at a 2.5-minute measurement interval) of total chlorine reagent and buffer solution; Sample Inlet Device
  • (330004) 3017M analyzer, DPD colorimetric method, measuring range 0-5 mg/L Cl2; 30-day supply (at a 2.5-minute measurement interval) of free chlorine reagent and buffer solution; Sample Inlet Device

  • Overview

    The YSI 3017M Chlorine Analyzer uses proven DPD methodology to provide accurate and reliable free chlorine or total chlorine measurements in drinking water and final effluent wastewater samples. The 3017M can also be used in aquatic habitats and industrial cooling tower applications.

    The 3017M is simple and low maintenance, with Flow Injection Analysis (FIA), factory calibration, and simplified tubing. Low reagent use reduces maintenance frequency. The analyzer can operate as a standalone unit or be integrated into YSI’s IQ SensorNet system of online controllers, analyzers, and sensors for better visibility and control of your process.

    The 3017M’s reliability and low-maintenance design ensure the collection of reliable data with minimal effort.

    • Accurate and reliable - Measures free or total chlorine in drinking water or municipal wastewater final effluent using the DPD colorimetric method. This highly accurate method of analysis provides reliable data for process optimization and reporting.
    • Low maintenance – Flow Injection Analysis (FIA) simplifies maintenance and saves you time. Simplified tubing and low reagent use reduce the frequency of instrument maintenance.
    • EPA & ISO compliant – The 3017M is compliant with US EPA regulations 40 CFR 141.74 (drinking water) and 40 CFR 136.3 (wastewater) and the 3017M measurement method conforms with standard method 4500-CL-G and US EPA method 334.0, which makes it suitable for drinking water permit reporting in the United States. In addition, the 3017M measurement method conforms with ISO method 7393-2.
    • Factory calibrated – Eliminates the need for regular calibration.

    Primary applications include:

    • Monitoring residual chlorine in drinking water for process optimization, alarming, and reporting.
    • Disinfection control, monitoring dechlorination, and process optimization in wastewater.

    Secondary applications include:

    • Monitoring chlorine levels in cooling towers to control corrosion and slime/algae build-up.
    • Monitoring chlorine levels in aquaculture and aquatic habitats to protect aquatic ecosystems.

  • Specifications
    WL430 Wastewater Level Sensor Electrical  
    Supply Voltage 8 - 38 Vdc
    Output

    4 - 20 mA

    Zero Balance ± 1% Full Scale Output (FSO)
    FSO Setting

    ± 1% FSO

    Resolution

    Infinite (±0.001% FSO usable)

    Response Time < 5 mS

    Insulation Resistance

    1000 MO @ 50 Vdc

    Reverse Polarity

    Protected

    Warm-Up < 10 mS
    Power Supply Effect = ± 0.002% FSO per V input
    EMI/RFI Internal Filtering
    Lightning Protected MOV and dual gas discharge tube
    Short Circuit Protected Up to 40 Vdc

     

    Wastewater Level Sensor Performance  
    Static Accuracy ± 0.5% FSO ( BFSL, RSS) (combined effects of non-linearity, hysteresis & repeatability)

    Repeatability

    ± 0.1% FSO

    Temperature Effects

    ± 1.5% FSO over comp range (combined effects of Zero & FSO with reference at 70°F)

    Long Term Stability ± 0.25% FSO per year

     

    Wastewater Level Sensor Performance  
    Pressure Ranges 10psi (23 ft) or 15psi (34 ft)
    Proof Pressure

    2x Full Scale

    Burst Pressure 5x Full Scale
    Materials

    316L SST plus cable

    Pressure Port

    Flush mount per outline

    Electrical Connector 1/2 inch-NPT Male submersible conduit fitting with 40ft of polyurethane cable

    Dimensions

    3 inch diameter x 6 inch long (7.6 cm dia. x 15 cm long)

    Weight

    Nominal 20 oz (.57 kg)

    Compensated Temp Range 20 to 170°F (-6 to 76°C)
    Operating Temp Range 0 to 200°F (-17 to 93°C)
    StorageTemp Range -20 to 250°F (-28 to 121°C)
  • Accessories

    3017M Tubing Set

    Replacement tubing set for 3017M

    Sample Inlet Device

    Sample Inlet Device for 3017M and 9220

    Reagent Caps

    Reagent caps for the 3017M reagent bottles

    Silicone Lubricant

    Silicone lubricant for the 3017M sample pump tube

You may also need

IQ SensorNet 2020 3G Controller

Modular water quality monitoring system for a complete sensor network that measures up to 20 parameters

$2,650.00

IQ SensorNet 282/284 Controller

Modular system for a complete sensor network ideal for various installation needs

Request Pricing

IQ SensorNet Analog Input Module

Analog input module that integrates third-party sensors and analyzers into the IQ SensorNet Network.

Request Pricing

3017M Tubing Set

Replacement tubing set for 3017M

$129.00

Sample Inlet Device

Sample Inlet Device for 3017M and 9220

Request Pricing

Replacement Filter for Sample Inlet Device

Replacement filter

Request Pricing