MultiLab FDO 4410 IDS Sensor

Price$1,153.00 (US Only)

Option

SKU201300Y


In Stock 3

Fluorescent dissolved oxygen (FDO) probe with temperature sensor

  • Overview

    The IDS FDO 4410 is a high-precision fluorescent dissolved oxygen (FDO) and temperature digital sensor optimized for use with YSI MultiLab benchtop instruments. With full YSI Water Monitoring Panel compatibility, it transitions seamlessly from benchtop measurements to 24/7 online monitoring.

    • Fluorescent DO measurement: Optical luminescence-based DO detection provides fast, stable readings with minimal maintenance.
    • Auto Recognition: Smart optical cap with a microchip that stores cap information and factory calibration; plug it in and the sensor updates instantly.
    • Smart Design: The 45° optical surface prevents micro-bubble accumulation, reducing the risk of falsely elevated DO readings.
    • Minimal Maintenance: No membranes, electrolyte, or routine calibration required. Optical DO technology removes the most time-consuming upkeep of traditional electrochemical sensors.

    Calibration
    Factory-calibrated optical DO technology eliminates routine calibration. Installing a new cap automatically updates calibration data. Verification checks may be performed per laboratory SOP.

    Model Options

    • 201300Y — IDS FDO 4410 (1.5 m cable)
    • 201301Y — IDS FDO 4410 (3 m cable)

    Want Wireless Capability?
    See the IDS FDO 4410W for full wireless flexibility with the same trusted performance.

    Platform Compatibility

    • MultiLab Platform: IDS sensors are fully compatible with YSI MultiLab benchtop meters, offering both wired and wireless options for consistent results and enhanced data integrity.
    • YSI Water Monitoring Panel (WMP): IDS sensors integrate seamlessly with the YSI WMP, providing plug-and-play connectivity for continuous monitoring. Calibration data transfers automatically for simplified maintenance and reduced downtime.

    Ordering Information
    For complete system setups, please refer to the MultiLab Ordering Guide. If you have questions about configuration or compatibility, contact us for support.

  • Specifications
    Accuracy

    Dissolved Oxygen Accuracy: +/- 1.5% of reading

    Temperature Accuracy: +/- 0.2°

    Cable Options Wireless, 1.5 m or 3 m
    Dimensions

    Cabled version: Sensor Length: 206 mm (8.1 in); Maximum: Diameter: 21.7 mm (0.85 in)
    Wireless version: Sensor Length: 252 mm (9.9 in) ; Maximum: Diameter: 21.7 (0.85 in)

    Measurement Range

    Dissolved Oxygen Range: 0 to 20 mg/L; 0 to 200% saturation

    Temperature Measurement Range: 0 to 50°C

    Operating Temperature 0 to 40°C
    Power Wireless module battery life 9 hours
    Resolution

    Dissolved Oxygen Resolution: 0.01 mg/L; 0.1%

    Temperature Resolution: 0.1°C

    Response Time 95% in 45 seconds
    Sensor Optical, lifetime luminescence detection, green light, not designed for BOD bottles.
    Warranty

    2 years, 1 year FDO sensor cap

You may also need

MultiLab IDS 4100 ProBOD Polarographic Probe

Self-stirring, polarographic, membrane-covered BOD probe

$964.00

Replacement Cap for MultiLab FDO Sensor

FDO replacement cap for MultiLab 4410 and 4410W sensors

$210.00

MultiLab 4010-2W

Two channel benchtop multiparameter instrument with wireless capability

$1,940.00

MultiLab IDS ProOBOD

Optical Self stirring BOD probe with temperature sensor, IDS

$1,199.00 - $1,393.00

MultiLab IDS 4130W pH and Temperature Wireless Sensor

Wireless pH and temperature, glass, 3 mol KCL, digital, double junction probe with refillable reference

$457.00