MultiLab IDS Kit

PriceRequest Pricing

Option

SKU626570


Laboratory instrument for pH, ORP, conductivity and BOD in any combination.

  • Overview

    626570 MultiLab BOD Lab Kit: MultiLab 4010-1W and OBOD probe

    626571 MultiLab Advanced BOD Lab Kit: MultiLab 4010-1W, OBOD probe, and BOD Analyst Pro PC software

    626572 MultiLab pH Lab Kit: MultiLab 4010-1W and pH electrode (dual junction combination electrode with integrated temperature sensor)

    626573 MultiLab BOD/pH Lab Kit: MultiLab 4010-2W, OBOD probe, and pH electrode (dual junction combination electrode with integrated temperature sensor)

    626574 MultiLab Advanced BOD/pH Lab Kit: MultiLab 4010-2W, OBOD probe, BOD Analyst Pro PC software, and pH electrode (dual junction combination electrode with integrated temperature sensor)

     

    The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory.

    The MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD in the laboratory. In addition, ISEs can be connected to the MultiLab 4010-2W and 4010-3W with the MultiLab BNC Adaptor.

    MultiLab instrument features:

    • Input for pH, ORP, DO/BOD, or conductivity sensors
    • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1W) or 10,000 (MultiLab 4010-2W/3W) data sets in automatic logging mode.
    • Large, easy to read graphic display. MultiLab 4010-2W/3W feature a color screen
    • Antibacterial keypad on the MultiLab 4010-2W/3W
    • Intelligent, digital sensors - plug and play sensors
    • GLP traceability (sensors store serial # and calibration data)
    • USB connectivity to manage data
    • 3-year warranty

    Intelligent Digital Sensors (IDS)

    The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

    • Plug and play connectivity with each instrument
    • IDS senors store their own unique ID with serial number and calibration data
    • Digital sensor recognition, processing and data transfer
    • Includes self-stirring BOD, pH, ORP and conductivity sensors
    • BOD probe uses optical dissolved oxygen technology and includes a guarded sensor tip

    CMC

    The CMC function displays continual monitoring of the sensor's measuring range. The range is represented with a bar and calibration points are shown as vertical lines at the cal point. A moving cursor shows the current measured value and indicates if the measurement is within the calibrated range.

    Quality Sensor Control

    QSC is a system to monitor the condition of the pH electrode. An initial calibration is performed and, afterwards, the sensor status is monitored and graphically displayed over time.

  • Specifications
    Autostable Yes
    Benchtop Yes
    Buffer Recognition Yes
    Certifications CE, cETLus
    Connectivity / Communications Mini USB, USB-A
    Data Management 500 data sets in manual mode and 5,000 data sets in automatic mode
    Digital / Digital Sensors Yes
    Display Large, easy to read graphic display
    Equipment used with Multilab IDS probes and accessories
    GLP Compliance Yes
    Graphic Display Large, easy to read graphic display
    Logging Capabilities Yes
    Measurement Method / Channels 1 Measurement Channel
    Measurement Range pH - 0.000 to 14.000 (+/-0.004), Conductivity - 10 µS/cm to 2,000 mS/cm +0.5% of value (301710Y), .01µS/cm to 200 µS/cm +0.5% of value (301720Y), TDS - 0 to 100ºC (32 to 212ºF), Dissolved Oxygen - 0 to 50 mgL; 0 to 500% air saturation, Salinity - 0.0 to 70.0 ppt +0.5% of value
    Operating pH Range 0.000 to 14.000 (+/-0.004)
    Operating Temperature 32 to 176º degrees F
    Parameters Measured Temperature, Conductivity, Resistivity, Salinity, TDS (Total Dissolved Solids), pH/mV, Oxidation Reduction Potential (ORP), Partial Pressure, Dissolved Oxygen (% and mg/L* (BOD)
    Power Universal power supply
    Sampling Yes
    Smart Sensors / Ports Intelligent Digital Sensors (IDS)
    User Calibratable Yes
    User Replaceable Yes
    Warranty 3 years
    Waterproof Yes
  • Accessories

    pH Buffer

    pH Buffer

    Conductivity Calibrator Solution

    Conductivity Calibrator Solution

  • Video

    YSI MultiLab Laboratory Meter | From the Box to the Lab

    The MultiLab instrument measures pH, ORP, conductivity, BOD and ion activity measurement. Connect digital Intelligent Digital Sensors (IDS) to the MultiLab 4010-3 for the measurement of pH, ORP, conductivity, and DO/BOD in any combination. Ion selective electrodes (ISE) can also be connected to the instrument. Find out all the other great features of the YSI MultiLab instrument in this video including the large, graphic display, plug-and-play connectivity, GLP traceability, USB connectivity to manage data, electrode stand, 3-year warranty and much more.

You may also need

TruLab pH/ISE 1320

Dual channel benchtop pH/ORP/ISE instrument

$1,885.31

MultiLab 4010-2/3 BNC Adapter

BNC pH/ORP/ISE adapter for MultiLab 4010-2/3 instruments

$220.48

MultiLab IDS ProOBOD

Optical Self stirring BOD probe with temperature sensor, IDS

$1,163.76 - $1,352.00

MultiLab 4010P-1W

Single channel benchtop multiparameter instrument with integrated printer

$1,796.08

MultiLab 4010-3W

Three channel benchtop multiparameter instrument with wireless capability

$2,427.36