Aurora 1030D TOC Analyzer

PriceRequest Pricing

SKU323051


Experience two types of TOC analysis in one powerful instrument! Use the Aurora 1030D to analyze TOC through the proven heated persulfate wet oxidation technique or the high temperature combustion method. Both modes have distinct chamber features to ensure accurate and reliable results.

  • Overview

    The Aurora 1030D TOC Analyzer is twice as efficient with its ability to analyze TOC by both the heated persulfate wet oxidation technique and high temperature combustion method. This allows for measurement of aqueous samples and other samples of a higher molecular weight all from one single instrument!

    Heated Persulfate Wet Oxidation

    The heated persulfate oxidation technique has been approved and adopted in numerous regulatory compliance methods, standards, and norms for water quality testing, including: Standard Method 5310C, USEPA 415.3, USP <643> / EU 2.2.44, ASTM D 4779 and 4839, USEPA-DBPR, USEPA-SPCC, ISO 8245, and EN 1484. 

    In wet oxidation mode the 1030D reaction chamber is thoroughly rinsed between analyses to eliminate residue from the previous sample. This ensures a low system background necessary for high sensitivity TOC measurements. 

    High Temperature Combustion

    High temperature (680 °C) catalytic combustion is most effective for samples containing high molecular weight, difficult-to-oxidize organics (e.g.; humic acid) at levels > 500 ppb C. Our patented two chamber combustion tube of the 1030D contains a bed of quartz in the first chamber to protect platinum catalyst in the second chamber from deposition of non-combustible constituents. This design extends catalyst life, ensures consistent oxidation conditions, and reduces instrument maintenance costs. 

     

  • Specifications

    Wet Oxidation Mode
     
    Operating Principle Heated sodium persulfate oxidation
    Measurement Range 10 ppb C - 30,000 ppm C (multiple calibration ranges or dilution required)
    Instrument Detection LImit (IDL) 2 ppb C
    Sample Injection Volume 10µL – 10mL
    Method TC Acid and persulfate reaction
    Method TIC Acidification with Phosphoric acid and sparging
    Method TOC NPOC by heated persulfate oxidation or TC - TIC
    Reagents Required Sodium persulfate, 5% phosphoric acid, rinsewater
    Gas Supply N2 (99.998%), zero-grade air, or O2 (99.998%)

     

    General Instrument Specifications  
    Measurement Technique Non-dispersive infrared (NDIR) detector
    Operator Interface Color LCD touchscreen display with Windows® CE-based software
    Basic Software Single instrument operation with data transfer to PC
    Optional ATOC Software Network LAN/LIMS operation, data management, custom reports, 21 CFR 11 compliance
    Autosampler 88 position rotary autosampler designed to fit directly underneath Aurora 1030D analyzer
    Certification CE, EMC: EN61326 / Safety: IEC 61010-11 2001
    Power Supply Variable voltage, 100-240VAC, 50/60Hz, 950W
    Dimensions – Aurora 1030D + 1088 Autosampler 26.75 in. H x 19.5 in. W x 23 in. D.
    Weight – Aurora 1030D + 1088 Autosampler 34.5 kg (76 lbs.) 
  • Accessories

You may also need

Aurora 1030W TOC Analyzer

TOC Analyzer

Request Pricing

1088 Rotary TOC Autosampler

Autosampler for TOC Analyzers

Request Pricing

ATOC Software

Automated Data Management Software

Request Pricing

1080 Total Organic Carbon (TOC) Analyzer

TOC Combustion Analyzer

Request Pricing

Flow Solution FS3700

Continuous Flow Analyzer

Request Pricing