Level Scout®
Level and Temperature
Accurate measurements, rugged design, and easy data management make the Level Scout ideal for groundwater monitoring, long-term surface water studies, resource management, aquifer/pump tests, Soil Vapor Extraction, wastewater intake monitoring and leachate monitoring.
YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI Level Scout® products and accessories.
Have a question about your YSI Level Scout®? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI Level Scout®.
Available with 2 or 4 mb memory, absolute or vented, and in stainless steel or titanium.
field cable features new, in-line vent filter that easily fits in a 1-inch well and does not require any maintenance since there is no desiccant to replace. Instead of using a replaceable desiccant, the filter vents the transducer to the atmoshpere to compensate for changes in barometric pressure through a waterproof patch. All vent tubes are internal to the vent filter so there is no need to worry about crimping the tube and affecting the readings. The cables are available with either a polyurethane jacket or a more chemically-resistant ETFE jacket.
Some benefits of using the Level Scout:
Data management is easy with Data Scout desktop software or Data Scout Mobile software for a pocket PC. Software is included with the purchase of any Level Scout instrument.
Level Scout Instrument General Specifications
| Approximate Weights | Transducer with batteries Cable assembly (less cable) Cable Suspension wire |
0.70 lbs (318g) |
| Batteries, Internal | 2 each 1.5 V AA alkaline recommended |
|
| Battery Life |
3 years 15-minute sampling intervals w/alkalines |
|
| Communication Interface |
RS-485; 3 volt p-p differential w/ selectable baud rates from 1200 to 19200 |
|
| Communication Protocol |
SDI-12 ver 1.3 compliant |
|
| Dimensions | Diameter Length |
0.75 in (19.0 mm) 12.44 in (316.00 mm) |
| External Excitation |
6 to 16 VDC |
|
| External Input Current | Avg current during measurement 15 mS peak current during page writes Quiescent |
8.0 mA 25.0 mA 0.25 mA |
| Protection Rating |
IP-68, NEMA 6P | |
| Temperature | Compensated Operating Storage without batteries Storage with batteries |
14 to 104°F (-10 to 40°C) -4 to 122°F (-20 to 50°C) -40 to 176°F (-40 to 80°C) -4 to 122°F (-20 to 50°C) |
Level Scout System Specifications
| Level Ranges |
||
| Full Scale Level Range |
10, 50, 75, 250, 692 ft. H2O (3, 15, 23, 76, 211 m H2O) |
for vented gauge reference |
| 10, 50, 70, 230, 692 ft. H2O (3, 15, 21, 70, 211 m H2O) |
for absolute reference | |
| Barometric Pressure Range |
8 to 16 psia (55 to 110 kPa) | for barometer |
| Proof Pressure | 1.5 x FS | |
| Burst Pressure |
2.0 x FS | |
|
Measurement Accuracy |
Standard | |
| Level | ±0.05 %FS TEB1,2 | for level ranges >10 ft. (3 m) H2O |
| ±0.10 %FS TEB1,2 | for level ranges <= 10 ft. (3 m) H2O | |
| Temperature | ±1.0°C | Models VS2, VT2, AS2, AT2 |
| ±0.2°C | Models VS4, VT4, AS4, AT4 | |
| 1. Total Error Band (TEB) includes the combined errors due to non-linearity, hysteresis, non-repeatablility, and thermal effects over the compensated temperature range per ISA S51.1 2. Additional error up to ±2% FS/year may be incurred due to offset drift |
||
Level Scout Data Logging Specifications
| Level Ranges |
||
| Data Upload Time | 100 scans/sec |
pressure and temp with time stamp per second @ 19200 baud rate |
| Maximum Pressure Scans | 196,560 with time stamp | Models VS2, VT2, AS2, AT2 |
| 393,120 with time stamp | Models VS4, VT4, AS4, AT4 |
|
| Maximum Pressure and Temperature Scans |
144,144 with time stamp | Models VS2, VT2, AS2, AT2 |
| 288,288 with time stamp | Models VS4, VT4, AS4, AT4 |
|
| Modes of Sampling | Linear, Linear Avg, Event, Logarithmic |
software selectable |
| Pressure Units |
psi, ft. H2O, mm H2O, cm H2O, m H2O, kPa | user-specified or by slope and offset |
| Sampling Rate 3 |
Programmable | 15 readings per second max |
| Time Stamp Accuracy |
±2 min/year |
over compensated temp range |
| 3. For sampling rates greater than 3 Hz, the pressure/temperature averaging must be reduced as required | ||
Ordering Guide
(Transducers, Cables, Communications Adapters Ordered Separately)
| Step 1: | Order Instrument |
| Item # |
Description |
| AS2-x2 | Absolute Level Scout, Stainless Steel, 2 Mb memory |
| AS4-x2 | Absolute Level Scout, Stainless Steel, 4 Mb memory |
| AT2-x2 | Absolute Level Scout, Titanium, 2 Mb memory |
| AT4-x2 | Absolute Level Scout, Titanium, 4 Mb memory |
| BS2 | Atmospheric compensation Baro Scout, Stainless Steel, 2 Mb memory |
| BS4 |
Atmospheric compensation Baro Scout, Stainless Steel, 4 Mb memory |
| VS2-x1 | Vented Level Scout, Stainless Steel, 2 Mb memory |
| VS4-x1 | Vented Level Scout, Stainless Steel, 4 Mb memory |
| VT2-x1 | Vented Level Scout, Titanium, 2 Mb memory |
| VT4-x1 | Vented Level Scout, Titanium, 4 Mb memory |
| 710 or 730-x3 |
Universal Cable, Stainless Steel or Titanium |
| 770 | Non-submersible quick disconnect communication cable |
| 750 or 760-x3 | Suspension Wire Assembly, Stainless Steel or Titanium |
| 771 | RS-485 to RS-232 converter and 6 foot RS-232 cable |
| 772 |
RS-485 to SDI-12 converter |
| 773 |
USB to RS-232 converter |
|
1. x = transducer rating available in depths of 10, 50, 75, 250, 692 feet (3, 15, 23, 76, 211 meters) |
|
Data Scout Software for the Level Scout - Operations Manual
Data Scout Advanced for the Level Scout - Operations Manual
YSI Level Scout Specifications
Français - YSI Level Scout Spécifications
Groundwater Applications & Capabilities
Water Quality Sampling for Field and Laboratory
Wastewater - Water quality capabilities & Solutions
Source Water Monitoring - Applications, Capabilities & Solutions
YSI Level Scouts® Monitor Groundwater Levels to Help Protect the Great Sphinx