6920DW
Monitor Drinking Water in Distribution System
The YSI 6920DW is a portable instrument which measures free chlorine, turbidity, and other parameters. Take readings at multiple points along a drinking water distribution system; the collected data gives you a comprehensive view of your water quality and can help you detect events of concern.
YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 6920DW products and accessories.
Have a question about your YSI 6920DW? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI 6920DW.
Data can be logged internally, sent to a SCADA system via the YSI 6500 Process Monitor, or viewed remotely and in real-time with YSI EcoNet.
Available parameters include:
Features:
YSI 6920DW Sonde Specifications
| Temperature | Operating |
-5 to +50°C |
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Memory | 150,000 data points | |
| Available Sensors | Free Chlorine, Conductivity, ORP, pH, Temperature, Turbidity | |
| Dimensions | Diameter Length Weight |
2.86 in, 7.3 cm 18.3 in, 46.4 cm 3.74 lbs, 1.7 kg |
| Power | External Internal |
12 V DC 8 AA-size alkaline batteries |
| Battery life | Approx. 20 days at 20˚C with a 15-min logging interval, 60-sec Cl2 warm-up, and turbidity active | |
YSI 6920DW Sensor Specifications
| Range | Resolution | Accuracy | ||
| Free Chlorine | 0 to 3 mg/L |
0.01 mg/L | ±15% of reading or 0.05 mg/L, whichever is greater* | |
| Conductivity• 6560 Sensor•• |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature 6560 Sensor•• |
-5 to +50°C | 0.01°C | ±0.15°C | |
| pH 6561 Sensor•• |
0 to 14 units | 0.01 unit | ±0.2 unit | |
| ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
| Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
| • Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). ••Sensors with listed with ETV logo were submitted to the ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at |
*to maintain accuracy specification, flow must be at least 500 mL/min and pH should not change by more than ±0.3 units if mean pH is greater than 8.5. |
|||
Drinking Water Monitoring Quick Start Guide
Drinking Water Sondes Operations Manual
Sonde Connector & Cable Field Reconditioning Procedure
YSI Drinking Water Sondes Specification Sheet
Source Water Monitoring Case Studies & Solutions
Source Water Monitoring - Applications, Capabilities & Solutions
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
Continuous Monitoring of Drinking Water Provides Assurance of Safety
Connecting 6-series Sondes to a PC via USB
|
|
3682 Zobell ORP Calibration SolutionYSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6144 Wiper Pads for Optical SensorsWiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes. |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6625 Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. |
|
|
|
6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher. |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
Locking Well CapLocking well cap for 2 or 4 inch wells. |
|
|
|
pH Sensors (6-Series)Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications. |
|
|
|
Turbidity Calibration SolutionsYSI turbidity solutions calibrate your instruments for maximum accuracy. |
|