
6920 V2
Compact Sonde for Unattended Monitoring
The YSI 6920 V2 sonde is an economical logging system, ideal for long-term in situ monitoring and profiling. Two versions:
YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 6920 V2 products and accessories.
Have a question about your YSI 6920 V2? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI 6920 V2.
Available optical sensors include ROX optical dissolved oxygen, blue-green algae, chlorophyll, turbidity, or rhodamine. A pressure sensor is an option on both versions. Additional parameters include:
Extend deployment intervals by 3 times or more with NEW Anti-Fouling Kits.
This product features:
Helpful information about water quality monitoring and long-term deployments at YSI's True Cost of Data web site and forum.
You can rely on the accuracy and reliability of YSI's sensor technology - the performance of select sensors on the 6920 V2 has been ETV Verified.*
Two versions are available:
| The 6920 V2-2 with | and the 6920 V2-1 with |
|
|
| Medium | Fresh, sea or polluted water | |
| Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Dimensions | Diameter Length Weight |
2.85 in, 7.24 cm 18 in, 45.7 cm 4 lbs, 1.8 kg |
| Power | External Internal |
12 V DC 8 AA-size alkaline batteries |
| Certifications |
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
|
| Range | Resolution | Accuracy | ||
| ROX™ Optical Dissolved Oxygen• % Saturation |
0 to 500% | 0.1% | 0 to 200%: ±1% of reading or 1% air saturation, whichever is greater; 200 to 500%: ±15% of reading |
|
| ROX™ Optical Dissolved Oxygen• mg/L |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.1 mg/L or 1% of reading, whichever is greater; 20 to 50 mg/L: ±15% of reading |
|
| Dissolved Oxygen•• % Saturation 6562 Rapid Pulse™ Sensor* |
0 to 500% | 0.1% | 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of reading |
|
| Dissolved Oxygen•• mg/L 6562 Rapid Pulse™ Sensor* |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater; 20 to 50 mg/L: ±6% of reading |
|
| Conductivity••• 6560 Sensor* |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature 6560 Sensor* |
-5 to +50°C | 0.01°C | ±0.15°C | |
| pH 6561 Sensor* |
0 to 14 units | 0.01 unit | ±0.2 unit | |
| ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
| Depth | Medium Shallow Vented Level |
0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
| Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
| Nitrate/nitrogen•••• | 0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
| Ammonium/ammonia/ nitrogen•••• |
0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
| Chloride•••• | 0 to 1000 mg/L | 0.001 to 1 mg/L (range dependent) |
±15% of reading or 5 mg/L, whichever is greater |
|
| Rhodamine• | 0-200 μg/L | 0.1 μg/L | ±5% reading or 1 μg/L, whichever is greater |
|
| • Maximum depth rating for all optical probes is 200 feet, 61 m. Turbidity and Rhodamine are also available in a Deep Depth option (0 to 200 m). •• Rapid Pulse is only available on 6920 V2-1 (one optical port version). ••• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). •••• Freshwater only. Maximum depth rating of 50 feet, 15.2 m. 6600 V2-2 has 3 ISE ports; not available on the 6600V2-4. |
**In YSI AMCO-AEPA Polymer Standards. | |||
| Range | Detection Limit | Resolution | Linearity | |
| Blue-Green Algae Phycocyanin• |
~0 to 280,000 cells/mL† 0 to 100 RFU |
~220 cells/mL§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999** |
| Blue-Green Algae Phycoerythrin• |
~0 to 200,000 cells/mL† 0 to 100 RFU |
~450 cells/mL§§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999*** |
| Chlorophyll• 6025 Sensor* |
~0 to 400 μg/L 0 to 100 RFU |
~0.1 μg/L§§§ | 0.1 μg/L Chl 0.1% RFU |
R2 > 0.9999**** |
| • Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m). RFU = Relative Fluorescence Units |
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. | § Estimated from cultures of Microcystis aeruginosa. §§ Estimated from cultures Synechococcus sp. §§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions. |
**For serial dilution of Rhodamine WT (0-400 ug/L). ***For serial dilution of Rhodamine WT (0-8 μg/L). ****For serial dilution of Rhodamine WT (0-500 ug/L). |
|
| *Sensors with listed with ETV logo were submitted to the ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at |
||||
6-Series Sonde Quick Start Guide
6-Series Multiparameter Water Quality Sondes User Manual
6-Series Sonde Calibration, Maintenance & Troubleshooting Tips
Sonde Connector & Cable Field Reconditioning Procedure
Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills
YSI 6820 and 6920 V2 Sonde Specifications
YSI 6131 and 6132 Blue-Green Algae Sensors
YSI ROX Optical Dissolved Oxygen Sensor
Groundwater Applications & Capabilities
Aquaculture Applications, Capabilities & Solutions
Español - Piscicultura Aplicaciones, Competencia y Soluciones
Monitoring Systems that Deliver Better Results from YSI Integrated Systems
Dissolved Oxygen Case Studies & Solutions
Source Water Monitoring - Applications, Capabilities & Solutions
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
6-Series Anti-Fouling Kits Prevent Biofouling, Extend Long-Term Deployments
River Quality Protected during Tyne Tunnel Construction Project
Catchment Monitoring Network Protects Thames River
Imposed Water Quality Conditions with Drought Permits
Ferry-linked Water Monitoring System Becomes New Model for United States
YSI Multiparameter Instruments Assist in Storm Water and Combined Sewer Overflow Monitoring
Maine Companies Partner to Protect Aquatic Life with YSI Integrated Systems
Drinking Water Monitoring with YSI Instruments and Systems
Monitoring Long-term Source Water Trends with the YSI 6500
Industrial Pretreatment Made More Efficient, Representative through the Use of YSI Technology
Connecting 6-series Sondes to a PC via USB
Deployment and Data Quality Assurance Tips
YSI 6562 Rapid Pulse™ Dissolved Oxygen Probe Membrane Maintenance
General O-Ring Care and Maintenance
Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes
|
|
3682 Zobell ORP Calibration SolutionYSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
5775 Standard DO MembranesYSI 5775 standard stretch-style dissolved oxygen membranes. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6025 Chlorophyll Sensor (6-Series)Determine phytoplankton concentrations by detecting the flourescence from chlorophyll in situ. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6130 Rhodamine Sensor (6-Series)Detect accurate, in situ trace dye levels with the 6130 Rhodamine Sensor. |
|
|
|
6131 and 6132 Blue-Green Algae Sensors (6-Series)Measure in situ blue-green algae levels in salt- or fresh-water with YSI 6131 and 6132 optical blue-green algae sensors. |
|
|
|
6136 Turbidity Sensor (6-Series)Collect accurate, in situ measurement of turbidity in fresh, brackish, and sea water. |
|
|
|
6144 Wiper Pads for Optical SensorsWiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes. |
|
|
|
6150 ROX ® Optical Dissolved Oxygen Sensor (6-Series)Rugged and reliable optical dissolved oxygen sensor used with 6-Series sondes. |
|
|
|
6155 Membrane Kit for ROX Optical DO SensorReplacement membrane kit for 6150 ROX optical dissolved oxygen sensor (6-series sondes). |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6425 Anti-fouling Optical Chlorophyll Sensor (6-Series)Copper-alloy anti-fouling optical chlorophyll sensor used with 6-Series sondes. |
|
|
|
6431 and 6432 Anti-fouling Optical Blue-Green Algae Sensors (6-Series)Copper-alloy anti-fouling optical blue-green algae sensor used with 6-Series sondes. |
|
|
|
6436 Anti-fouling Optical Turbidity Sensor (6-Series)Copper-alloy anti-fouling optical turbidity sensor used with 6-Series sondes. |
|
|
|
6450 Anti-fouling ROX ® Optical Dissolved Oxygen Sensor (6-Series)Copper-alloy anti-fouling optical dissolved oxygen sensor used with 6-Series sondes. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6562 Rapid Pulse Dissolved Oxygen SensorObtain unprecedented accuracy and reliability with the YSI 6562 Rapid Pulse™ Dissolved Oxygen Sensor. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6624 Wiper Kit for Chlorophyll and Rhodamine SensorsReplacement wipers for 6-series 6025 Chlorophyll probe or 6130 Rhodamine WT probe. |
|
|
|
6625 Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. |
|
|
|
6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher. |
|
|
|
6882, 6883, 6884 Nutrient Ion-Selective-Electrode Sensors (6-Series)Measure Nutrient Data with Nitrate, Ammonium, and Chloride with Ion Selective Electrodes |
|
|
|
6885 Sonde Weight KitWeight kit for 6820 or 6920 sondes. |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Anti-fouling Copper TapeCopper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths. |
|
|
|
Anti-fouling Sensor Port PlugsCopper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection. |
|
|
|
Anti-fouling Sensor ScreenCopper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes. |
|
|
|
Anti-fouling Sonde GuardsCopper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
pH Sensors (6-Series)Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications. |
|
|
|
Turbidity Calibration SolutionsYSI turbidity solutions calibrate your instruments for maximum accuracy. |
|