
6600V2
Make the most of your environmental monitoring.
The YSI 6600 V2 data sonde is the most comprehensive water quality monitoring equipment available with simultaneous measurement of conductivity (salinity), temperature, depth or level, pH/ORP plus...

YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 6600V2 products and accessories.
Have a question about your YSI 6600V2? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you'll find authorized service centers and instructions on how to send in your YSI 6600V2.
The 6600 V2-4 also measures these parameters: dissolved oxygen, turbidity, chlorophyll, and blue-green algae; the V2-2 measures two of the four parameters simultaneously. Additional calculated parameters include total dissolved solids, resistivity, and specific conductance.
Utilize YSI’s new optical sensor design and anti-fouling wiper control for improved reliability during extended deployments.
Find helpful information about water quality monitoring and long-term deployments at YSI's True Cost of Data web site and forum.
Take Advantage of YSI’s New Optical Sensors
In addition to turbidity, chlorophyll, and rhodamine, YSI offers these optical sensors:
ROX Reliable Optical Dissolved Oxygen
The ROX sensor uses lifetime luminescence detection technology to offer the most reliable oxygen sensor with the lowest possible maintenance effort. The sensor is insensitive to hydrogen sulfide
interference and does not require regular membrane changes.
Blue-Green Algae (BGA)
YSI’s fluorescence-based blue-green algae sensors will allow you to monitor blue-green algae populations where their presence is a concern. Whether providing an early warning to an algal bloom, tracking taste and odor-causing species in drinking water supplies, or conducting ecosystem research, YSI BGA sensors will provide sensitive and reliable in situ data.
Sensor performance verified*
The 6600 V2 sonde uses sensor technology that was verified through the US EPA’s Environmental Technology Verification Program (ETV).
6600 Upgrades Available
YSI is committed to offering our customers reliable and cost-effective water monitoring solutions. To this end, we are offering V2 Upgrades for existing 6600s. Upgrades will be available from YSI Authorized Service Centers and will include the new 6600 V2 bulkhead, a ROX Optical Dissolved Oxygen Sensor, and firmware/software upgrades. In addition, the sonde will be fully tested and calibrated by an experienced YSI service technician.
Related Products |
|||
|
EXO1 Water Quality Sonde |
EXO2 Water Quality Sonde |
EXO Handheld |
Multiparameter Sondes |
|
6920 V2 |
6820 V2 |
600OMS V2 |
600XL V2 and 600XLM V2 |
|
600LS |
EcoNet |
|
Two versions are available:
| The 6600 V2-4 with | and the 6600 V2-2 with |
|
|
| Medium | Fresh, sea or polluted water | |
| Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Dimensions | Diameter Length, no depth Length, with depth Weight |
3.5 in, 8.9 cm 19.6 in, 49.8 cm 21.6 in, 54.9 cm 7 lbs, 3.18 kg (batteries installed, with depth) |
| Power | External Internal |
12 V DC 8 C-size alkaline batteries |
| Certifications |
|
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
| Range | Resolution | Accuracy | ||
| ROX™ Optical Dissolved Oxygen• % Saturation |
0 to 500% | 0.1% | 0 to 200%: ±1% of reading or 1% air saturation, whichever is greater; 200 to 500%: ±15% of reading |
|
| ROX™ Optical Dissolved Oxygen• mg/L |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.1 mg/L or 1% of reading, whichever is greater; 20 to 50 mg/L: ±15% of reading |
|
| Dissolved Oxygen•• % Saturation 6562 Rapid Pulse™ Sensor* |
0 to 500% | 0.1% | 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of reading |
|
| Dissolved Oxygen•• mg/L 6562 Rapid Pulse™ Sensor* |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater; 20 to 50 mg/L: ±6% of reading |
|
| Conductivity••• 6560 Sensor* |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature 6560 Sensor* |
-5 to +50°C | 0.01°C | ±0.15°C | |
| pH 6561 Sensor* |
0 to 14 units | 0.01 unit | ±0.2 unit | |
| ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
| Depth | Deep Medium Shallow Vented Level |
0 to 656 ft, 200 m 0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±1 ft, ±0.3 m ±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
| Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
| Nitrate/nitrogen•••• | 0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
| Ammonium/ammonia/ nitrogen•••• |
0 to 200 mg/L-N | 0.001 to 1 mg/L-N (range dependent) |
±10% of reading or 2 mg/L, whichever is greater |
|
| Chloride•••• | 0 to 1000 mg/L | 0.001 to 1 mg/L (range dependent) |
±15% of reading or 5 mg/L, whichever is greater |
|
| Rhodamine• | 0-200 μg/L | 0.1 μg/L | ±5% reading or 1 μg/L, whichever is greater |
|
| • Maximum depth rating for optical probes is 200 feet, 61 m. Turbidity and Rhodamine are available in a Deep Depth option (0 to 200 m). Anti-fouling optical probes have depth rating of 200 m. •• Rapid Pulse is only available on 6600 V2-2 (two optical ports version). ••• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). •••• Freshwater only. Maximum depth rating of 50 feet, 15.2 m. 6600 V2-2 has 3 ISE ports; not available on the 6600V2-4. |
**In YSI AMCO-AEPA Polymer Standards. | |||
| Range | Detection Limit | Resolution | Linearity | |
| Blue-Green Algae Phycocyanin• |
~0 to 280,000 cells/mL† 0 to 100 RFU |
~220 cells/mL§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999** |
| Blue-Green Algae Phycoerythrin• |
~0 to 200,000 cells/mL† 0 to 100 RFU |
~450 cells/mL§§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999*** |
| Chlorophyll• 6025 Sensor* |
~0 to 400 μg/L 0 to 100 RFU |
~0.1 μg/L§§§ | 0.1 μg/L Chl 0.1% RFU |
R2 > 0.9999**** |
| • Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m). RFU = Relative Fluorescence Units |
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. | § Estimated from cultures of Microcystis aeruginosa. §§ Estimated from cultures Synechococcus sp. §§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions. |
**For serial dilution of Rhodamine WT (0-400 ug/L). ***For serial dilution of Rhodamine WT (0-8 μg/L). ****For serial dilution of Rhodamine WT (0-500 ug/L). |
|
| *Sensors with listed with ETV logo were submitted to the U.S. EPA ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at |
||||
6-Series Sonde Quick Start Guide
6-Series Multiparameter Water Quality Sondes User Manual
6-Series Sonde Calibration, Maintenance & Troubleshooting Tips
Sonde Connector & Cable Field Reconditioning Procedure
Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills
YSI Presentation: Collecting High-Quality Water Monitoring Data in the Field
Power and Communication System (PACS)
YSI Photosynthetically Active Radiation (PAR) Sensor
YSI 6600 V2 Sonde Specifications
YSI Wiped pH and pH/ORP Sensors
YSI 6131 and 6132 Blue-Green Algae Sensors
YSI ROX Optical Dissolved Oxygen Sensor
Groundwater Applications & Capabilities
Aquaculture Applications, Capabilities & Solutions
Español - Piscicultura Aplicaciones, Competencia y Soluciones
Monitoring Systems that Deliver Better Results from YSI Integrated Systems
Source Water Monitoring Case Studies & Solutions
Dissolved Oxygen Case Studies & Solutions
Source Water Monitoring - Applications, Capabilities & Solutions
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
Japanese - YSI 6シリーズ 多項目水質モニター
Historic Voyage in Chesapeake Bay Provides Unique Water Quality Data Set
Colorado Non-profit Manages Influx of Water Quality Data for Healthy Headwaters
6-Series Anti-Fouling Kits Prevent Biofouling, Extend Long-Term Deployments
Network Monitors Water Quality in Shale Gas Drilling Region
Water Quality Is Key to the Success of Cardiff Bay Restoration
Real-time Monitoring through Swell and High Water
Employing Best Monitoring Practices to Reduce Runoff
Desalination Plants: YSI Instruments Monitor Flow & Water Quality at Multiple Stages
Continuous Monitoring of Turbidity in Ohio Rivers Using Modified Sidestream Method
Anti-Fouling Kits Significantly Slow Rate of Biological Fouling on Water Quality Instruments
Catchment Monitoring Network Protects Thames River
Vertical Profiling Safeguards Drinking Water and Sheds Light on Cyanobacteria
Considerations for Sea Cage Aquaculture in Marine Environments
Managing the Demand for Clean, Safe Water in the Middle of Nutrient-Laden Farmland
Public-Private Contract Safeguards Malaysia’s Water Quality
Reclaiming the Land for Wetlands
Sending Ferries to Uncover the Secrets of the Sea
Thames Water Employs Reservoir Profi ler to Reduce Costs
Monitoring and Protecting Water Quality in Lake Mead, Nevada
Real-time Continuous Nitrate Monitoring Provides a Window on Nutrient Loading in Lake Pontchartrain
Dubai Municipality Utilizes YSI Real-time Water Quality Monitoring Instrumentation
YSI Multiparameter Instruments Assist in Storm Water and Combined Sewer Overflow Monitoring
Integrating Coral Reef Ecosystem Management with Watershed-based Activities
Sustainable Seas Expedition Includes YSI 6600 Sonde
Southampton Oceanography Centre Searches for Clues on Harmful Algal Blooms with the YSI 6600
YSI Real-time Water Quality Monitoring and the IPSWATCH-EMPACT Program
Connecting 6-series Sondes to a PC via USB
Deployment and Data Quality Assurance Tips
General O-Ring Care and Maintenance
Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes
YSI Instruments EPA Compliance Guide
YSI's Mike Lizotte and Tom Moeggenberg present a free, informative webinar about making accurate turbidity measurements in marine and fresh waters.
Topics include:
• YSI Turbidity Sensor Technology
• Choosing the right calibration standard
• Turbidity probe calibration procedures, and the use of offsets
• Best practices for long-term measurements
• Anti-fouling techniques
• Post-calibration techniques for sampling and long-term studies
• Q&A
Who should listen:
• Those using submersible field sensors for water quality sampling and monitoring
• Those measuring turbidity for storm water, construction run-off, flood events, TMDLs or other water quality concerns
|
|
116275 Extended Calibration CupExtended length calibration cup assembly for 6600V2-2, 6600EDS V2-2, and 6600V2-4 sondes. |
|
|
|
3682 Zobell ORP Calibration SolutionYSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
5775 Standard DO MembranesYSI 5775 standard stretch-style dissolved oxygen membranes. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6025 Chlorophyll Sensor (6-Series)Determine phytoplankton concentrations by detecting the fluorescence from chlorophyll in situ. |
|
|
|
6035 Reconditioning KitReconditioning kit for 6562 Rapid Pulse dissolved oxygen electrodes. |
|
|
|
6044 Sonde Weight3-pound weight for 6600 sonde. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6130 Rhodamine Sensor (6-Series)Detect accurate, in situ trace dye levels with the 6130 Rhodamine Sensor. |
|
|
|
6131 and 6132 Blue-Green Algae Sensors (6-Series)Measure in situ blue-green algae levels in salt- or fresh-water with YSI 6131 and 6132 optical blue-green algae sensors. |
|
|
|
6136 Turbidity Sensor (6-Series)Collect accurate, in situ measurement of turbidity in fresh, brackish, and sea water. |
|
|
|
6144 Wiper Pads for Optical SensorsWiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes. |
|
|
|
6150 ROX ® Optical Dissolved Oxygen Sensor (6-Series)Rugged and reliable optical dissolved oxygen sensor used with 6-Series water quality sondes. |
|
|
|
6155 Membrane Kit for ROX Optical DO SensorReplacement membrane kit for 6150 ROX optical dissolved oxygen sensor (6-series sondes). |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6425 Anti-fouling Optical Chlorophyll Sensor (6-Series)Copper-alloy anti-fouling optical chlorophyll sensor used with 6-Series sondes. |
|
|
|
6431 and 6432 Anti-fouling Optical Blue-Green Algae Sensors (6-Series)Copper-alloy anti-fouling optical blue-green algae sensor used with 6-Series sondes. |
|
|
|
6436 Anti-fouling Optical Turbidity Sensor (6-Series)Copper-alloy anti-fouling optical turbidity sensor used with 6-Series sondes. |
|
|
|
6450 Anti-fouling ROX ® Optical Dissolved Oxygen Sensor (6-Series)Copper-alloy anti-fouling optical dissolved oxygen sensor used with 6-Series sondes. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6562 Rapid Pulse Dissolved Oxygen SensorObtain unprecedented accuracy and reliability with the YSI 6562 Rapid Pulse™ Dissolved Oxygen Sensor. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6601 Flow CellThe 6601 flow cell simply screws onto the bottom of the calibration/transport cup of a 6600 sonde to turn it into a convenient flow cell. |
|
|
|
6624 Wiper Kit for Chlorophyll and Rhodamine SensorsReplacement wipers for 6-series 6025 Chlorophyll probe or 6130 Rhodamine WT probe. |
|
|
|
6625 Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. |
|
|
|
6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher. |
|
|
|
6882, 6883, 6884 Nutrient Ion-Selective-Electrode Sensors (6-Series)Measure Nutrient Data with Nitrate, Ammonium, and Chloride with Ion Selective Electrodes |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Anti-fouling Copper TapeCopper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths. |
|
|
|
Anti-fouling Sensor Port PlugsCopper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection. |
|
|
|
Anti-fouling Sensor ScreenCopper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes. |
|
|
|
Anti-fouling Sonde GuardsCopper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
pH Sensors (6-Series)Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications. |
|
|
|
Photosynthetically Active Radiation (PAR) SensorMeasure Photosynthetically Active Radiation levels via sensors integrated into a 6600 Sonde. |
|
|
|
Sensor Adapter KitExpand your water quality monitoring to include hydrocarbons, oil, or CDOM with the YSI Sensor Adapter and Turner Cyclops-7 submersible sensors. The YSI 202400 Sensor Adapter expands water quality monitoring to include third-party analog output sensors. In addition to monitoring for Temperature, Conductivity, pH, Dissolved Oxygen, Turbidity, Blue-Green Algae, and Chlorophyll, 6-Series sondes can measure hydrocarbons, oil in water, and other parameters from the Turner Cyclops-7® submersible sensor line. |
|
|
|
Turbidity Calibration SolutionsYSI turbidity solutions calibrate your instruments for maximum accuracy. Extremely accurate and stable solutions. |
|