Multiparameter Sondes

EXO1

EXO2

6600 V2

6920 V2

600OMS V2

Legacy Sondes

All Legacy Sondes

CTD

CastAway CTD

Process Monitors

IQ SensorNet 2020 XT

IQ SensorNet 182

Aquaculture Systems

5200A Multiparameter

5400 MultiDO

5500 MultiDO Optical

AquaViewer App

All YSI Accessories - Sensors, Cables, Calibration Solutions & more...

Professional Series

Handheld Instruments

Pro Plus Multiparameter

ProODO Optical DO/OBOD

Pro20 Lab/Field DO

Pro2030 Field DO/Cond

Pro30 Field Cond

Classic Handheld Series

556MPS Multiparameter

550A Dissolved Oxygen

63 pH/Conductivity

60 pH

58 Lab/Field DO

55 Dissolved Oxygen

Colorimeters

900 Chlorine

910 COD

pHotoFlex Colorimeters

Laboratory Series

pH1200

5000/5100 BOD/DO

3200 Conductivity

3100 Conductivity

MultiLab 4010-1

MultiLab 4010-2

MultiLab 4010-3

3100 Conductivity

EcoSense

pH10A - pH Pen

pH100A - pH

ORP15A - ORP Pen

DO200A - DO

EC30A - Conductivity Pen

EC300A - Conductivity

9300/9500 Photometer

YSI Systems

Buoys & Floating Platforms

EcoMapper AUV

EcoNet Data-to-Web

Vertical Profiling

Towed Underwater Vehicles

Underway Sampling System

Other YSI Products

SonTek Acoustic Doppler Systems for water velocity

YSI Systems

DAA WaterLog

YSI Life Sciences

Ammonia/Ammonium

Blue-Green Algae

BOD (Biochemical Oxygen Demand)

CDOM

Chloride

Chlorophyll

Conductivity

Depth

Dissolved Oxygen

Free Chlorine

Level

Nitrate

Oil / Hydrocarbon

ORP / Redox

Photosynthetic Active Radiation (PAR)

pH

Resistivity

Rhodamine

Salinity

Specific Conductance

Temperature

Total Dissolved Solids (TDS)

Turbidity

Colorimeter Parameters

Photometer Parameters

Aquaculture

Coastal

Desalination

Estuary

Drinking Water

Groundwater

Hydraulic Fracturing

Laboratory

Oceans

Raw Water

Source Water

Storm Water

Surface Water

Wastewater

Watersheds / TMDL

Ask a Question

Events & Training

Find a Distributor

Product Service

Resource Library

Software Downloads

Welcome from the GM

History

News

Career Opportunities

Environmental Stewardship

Sustainability

Quality

Xylem Watermark

YSI - a xylem brand
Find YSI on Facebook Follow YSI on Twitter Watch YSI on YouTube
Login | Register
Loading

6600EDS

Product Recycling Recycling

Pin It

Extended Deployment for Harsh Environments

 

The 6600EDS multiparameter sonde accurately measures 10 parameters in severe fouling environments for extended periods. The sonde has two optical ports, conductivity/temperature port, Rapid Pulse DO port, and pH/ORP port. The 6600EDS also offers an extended brush that cleans the pH/ORP and Rapid Pulse DO sensors.

This product has received the EA's MCERTS Certification
The YSI 6600EDS showing Turbidity (center) with attached wiper brush, Clockwise from top: Chlorophyll, pH/ORP, Temperature/Conductivity, and Rapid Pulse Dissolved Oxygen Sensors.
Send me a Quote!

Find a Distributor

YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 6600EDS products and accessories.

Find a Distributor

Get Support

Have a question about your YSI 6600EDS? Check out the support page with resources compiled just for you.

Contact Technical Support

Product Service Centers

Want to return a product for service? Here you'll find authorized service centers and instructions on how to send in your YSI 6600EDS.

Product Service

Field studies of the 6600EDS demonstrate that the system provides DO accuracy in aggressive biofouling environments. In one example, the 6600EDS V2 was inspected on the 80th day of an ongoing deployment performance evaluation. The Rapid Pulse™ DO sensor performed within specifications throughout this deployment without the need for recalibration or cleaning.

Now extend deployment intervals by 3 times or more with NEW Anti-Fouling Kits.

Parameters include:

  • Conductivity/Temperature
  • Dissolved Oxygen
  • Salinity
  • Specific Conductance
  • Depth
  • TDS
  • Shallow Vented Level
  • Turbidity and
  • Chlorophyll, Blue-green Algae or Rhodamine

You can rely on the accuracy and reliability of YSI's sensor technology. The performance of the sensors on the 6600EDS has been ETV Verified.*

Features

  • Wiped anti-fouling protection
  • Ideal for long-term deployments in extreme fouling environments
  • Virtually maintenance free
  • Field-replaceable sensors

Related Products


YSI water quality sondes - legacy





Legacy Sondes
YSI 6820 V2 showing sensors, starting clockwise from top: ROX Optical Dissolved Oxygen, Turbidity, pH, ISE, and temperature/condutivity.





6820 V2
YSI 600XLM V2 shown without probe guard.





600XL V2 and 600XLM V2
YSI 600XL with 650 MDS Handheld display and Flow Cell.





600XL and 600XLM

 

YSI 600QS 'Quick Sample'





600QS
YSI 600R shown with probe guard attached.





600R
YSI 600LS 'Level Sonde' shown with probe guard attached.





600LS
YSI 6920DW showing sensors, clockwise from top: pH/ORP, Temperature/Conductivity, Free Chlorine, Turbidity.





6920DW

 

YSI 600DW-B shown in profile with probe guard removed.





600DW
YSI 650MDS Display and Logging System





650MDS
YSI 6500 Process Monitor





6500 Process Monitor
YSI 6-Series Anti-fouling Sensors and Wipers





6-Series Anti-Fouling Kits

 

 

 

 

 

Medium Fresh, sea or polluted water
Temperature Operating
Storage
-5 to +50°C
-10 to +60°C
Communications RS-232, SDI-12
Software EcoWatch®
Dimensions Diameter
Length, no depth
Length, with depth
Weight
3.5 in, 8.9 cm
19.6 in, 49.8 cm
21.6 in, 54.9 cm
7 lbs, 3.18 kg (batteries installed, with depth)
Power External
Internal
12 V DC
8 C-size alkaline batteries
Certifications

CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS
Assembled in the USA

 

Range Resolution Accuracy
Dissolved Oxygen••
% Saturation
6562 Rapid Pulse™ Sensor*
0 to 500% 0.1% 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater;
200 to 500%: ±6% of reading
Dissolved Oxygen••
mg/L
6562 Rapid Pulse™ Sensor*
0 to 50 mg/L 0.01 mg/L 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater;
20 to 50 mg/L: ±6% of reading
Conductivity•••
6560 Sensor*
0 to 100 mS/cm 0.001 to 0.1 mS/cm
(range dependent)
±0.5% of reading + 0.001 mS/cm
Salinity 0 to 70 ppt 0.01 ppt ±1% of reading or 0.1 ppt,
whichever is greater
Temperature
6560 Sensor*
-5 to +50°C 0.01°C ±0.15°C
pH
6561 Sensor*
0 to 14 units 0.01 unit ±0.2 unit
ORP -999 to +999 mV 0.1 mV ±20 mV
Depth Deep
Medium
Shallow
Vented Level
0 to 656 ft, 200 m
0 to 200 ft, 61 m
0 to 30 ft, 9.1 m
0 to 30 ft, 9.1 m
0.001 ft, 0.001 m
0.001 ft, 0.001 m
0.001 ft, 0.001 m
0.001 ft, 0.001 m
±1 ft, ±0.3 m
±0.4 ft, ±0.12 m
±0.06 ft, ±0.02 m
±0.01 ft, 0.003 m
Turbidity•
6136 Sensor*
0 to 1,000 NTU 0.1 NTU ±2% of reading or 0.3 NTU,
whichever is greater**
Rhodamine• 0-200 μg/L 0.1 μg/L ±5% reading or 1 μg/L,
whichever is greater
• Maximum depth rating for optical probes is 200 feet, 61 m. Turbidity and Rhodamine are available in a Deep Depth option (0 to 200 m). Anti-fouling optical probes have depth rating of 200 m.
•• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided.
These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989).
**In YSI AMCO-AEPA Polymer Standards.

 

Range Detection Limit Resolution Linearity
Blue-Green Algae
Phycocyanin•
~0 to 280,000 cells/mL†
0 to 100 RFU
~220 cells/mL§ 1 cell/mL
0.1 RFU
R2 > 0.9999**
Blue-Green Algae
Phycoerythrin•
~0 to 200,000 cells/mL†
0 to 100 RFU
~450 cells/mL§§ 1 cell/mL
0.1 RFU
R2 > 0.9999***
Chlorophyll•
6025 Sensor*
~0 to 400 μg/L
0 to 100 RFU
~0.1 μg/L§§§ 0.1 μg/L Chl
0.1% RFU
R2 > 0.9999****
Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m).
RFU = Relative Fluorescence Units
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. § Estimated from cultures of Microcystis aeruginosa.
§§ Estimated from cultures Synechococcus sp.
§§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions.
**For serial dilution of Rhodamine WT (0-400 ug/L).
***For serial dilution of Rhodamine WT (0-8 μg/L).
****For serial dilution of Rhodamine WT (0-500 ug/L).
*Sensors with listed with ETV logo were submitted to the U.S. EPA ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at 800.897.4151 800.897.4151 for the ETV verification report. Use of ETV name or logo does not imply approval or certification of this product nor does it make any explicit or implied warranties or guarantees as to product performance.

Manuals

6-Series Sonde Quick Start Guide

6-Series Multiparameter Water Quality Sondes User Manual

Tips, FAQs & Guides

6-Series Sonde Calibration, Maintenance & Troubleshooting Tips

Sonde Connector & Cable Field Reconditioning Procedure

6-Series pH Sensors Overview

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

Specification Sheets

YSI Photosynthetically Active Radiation (PAR) Sensor

YSI 6136 Turbidity Sensor

6600EDS Extended Deployment System Specifications

YSI Rhodamine Sensor

YSI Chlorophyll Sensor

YSI 6131 and 6132 Blue-Green Algae Sensors

Catalogs & Brochures

Aquaculture Applications, Capabilities & Solutions

Español - Piscicultura Aplicaciones, Competencia y Soluciones

Water Monitoring Solutions

6-Series Multiparameter Water Quality Sondes

Français - Sondes multiparamètres série 6 surveillance des eaux

Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden

Japanese - YSI 6シリーズ 多項目水質モニター

News Briefs

YSI Water Quality Instruments Assist in Olympic Game Preparations

6-Series Anti-Fouling Kits Prevent Biofouling, Extend Long-Term Deployments

Application Notes

Using Real-time Telemetry for Ecological Monitoring of Coastal Wetlands

Pontoon-Mounted Autonomous Monitoring System Keeps Constant Watch on Harmful Algal Blooms

Unattended Water Quality Monitoring Protects Domestic Water Supply at Taiwan’s Shimen Reservoir

Monitoring the Water Quality of Lake Olathe and Protecting Drinking Water for Olathe Residents

Ambitious Water Quality Study Could Guide Florida City Development for Years

Building a Baseline in Florida: Massive flow of data will put science at the center of standards debate

Czechs Buy Water Quality Data—Not Instruments

Dubai Municipality Utilizes YSI Real-time Water Quality Monitoring Instrumentation

Extended Deployment Appeals to Users Worldwide

Integrating Coral Reef Ecosystem Management with Watershed-based Activities

Scientists and Alternative in situ Technology Work to Protect Seminole County Water Quality

NCSU Study Reveals YSI 6600EDS Performs Well in High Fouling Conditions

Technical Notes

Connecting 6-series Sondes to a PC via USB

Deployment and Data Quality Assurance Tips

YSI 6562 Rapid Pulse™ Dissolved Oxygen Probe Membrane Maintenance

General O-Ring Care and Maintenance

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

MCERTS Certifications

MCERTS - YSI 6600 Sondes

Compliance Certifications

YSI Instruments EPA Compliance Guide

Webinars

Archived Webinar:
Making Better Turbidity Measurements in Ambient Water



Original Broadcast: November 4, 2010 —1-2 PM EDT (US)

YSI's Mike Lizotte and Tom Moeggenberg present a free, informative webinar about making accurate turbidity measurements in marine and fresh waters.

Topics include:
•  YSI Turbidity Sensor Technology
•  Choosing the right calibration standard
•  Turbidity probe calibration procedures, and the use of offsets
•  Best practices for long-term measurements
•  Anti-fouling techniques
•  Post-calibration techniques for sampling and long-term studies
•  Q&A

Who should listen:
•  Those using submersible field sensors for water quality sampling and monitoring
•  Those measuring turbidity for storm water, construction run-off, flood events, TMDLs or other water quality concerns

 

YSI 6600 sonde extended calibration cup.
 

116275 Extended Calibration Cup

Extended length calibration cup assembly for 6600V2-2, 6600EDS V2-2, and 6600V2-4 sondes.

Sonde power and communication system with vehicle
 

202350 PACS-1 Power and Communication System

Get Water Data with Bluetooth® Wireless Technology and Solar Power. The YSI Power and Communication System (PACS) supplies continuous power to submerged water instrumentation and enables wireless communication with the instrumentation.

YSI 3682 Zobell ORP Calibration Solution
 

3682 Zobell ORP Calibration Solution

YSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments.

YSI pH 4, 7 and 10 buffers
 

3824 Assorted pH Buffers Case

Various pH buffers for pH probe calibration.

YSI Confidence Solution to Check pH, ORP, Conductivity
 

5580 Confidence Solution®

Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®.

YSI 5775 Standard Stretch-Style DO Membranes
 

5775 Standard DO Membranes

YSI 5775 standard stretch-style dissolved oxygen membranes.

YSI 6-series field cable
 

6-Series Field Cables

Rugged cables designed for field use with 6-series sondes.

6025 Chlorophyll Sensor
 

6025 Chlorophyll Sensor (6-Series)

Determine phytoplankton concentrations by detecting the fluorescence from chlorophyll in situ.

6035 Rapid Pulse DO Resurfacing Kit
 

6035 Reconditioning Kit

Reconditioning kit for 6562 Rapid Pulse dissolved oxygen electrodes.

6044 weight for 6600 sondes.
 

6044 Sonde Weight

3-pound weight for 6600 sonde.

Indoor-use adapter cable
 

6067B Adapter Cables

YSI 6-series sonde to RS-232 adapter. Indoor-use only.

Field cable to RS-232 adapter.
 

6095B Adapter Cable

YSI 6-series field cable to RS-232 adapter.

PC Interface cable for 650MDS.
 

6112 PC Interface Cable for 650MDS

MS-8 to pc serial port connector for 650MDS.

6130 Rhodamine Sensor
 

6130 Rhodamine Sensor (6-Series)

Detect accurate, in situ trace dye levels with the 6130 Rhodamine Sensor.

Blue-Green Algae Probe
 

6131 and 6132 Blue-Green Algae Sensors (6-Series)

Measure in situ blue-green algae levels in salt- or fresh-water with YSI 6131 and 6132 optical blue-green algae sensors.

6136 Optical Turbidity Sensor
 

6136 Turbidity Sensor (6-Series)

Collect accurate, in situ measurement of turbidity in fresh, brackish, and sea water.

Optical probe wiper pad kit.
 

6144 Wiper Pads for Optical Sensors

Wiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes.

YSI ROX Dissolved Oxygen Probe
 

6150 ROX ® Optical Dissolved Oxygen Sensor (6-Series)

Rugged and reliable optical dissolved oxygen sensor used with 6-Series water quality sondes.

New 6155 membrane
 

6155 Membrane Kit for ROX Optical DO Sensor

Replacement membrane kit for 6150 ROX optical dissolved oxygen sensor (6-series sondes).

Zinc anode on 600 sonde.
 

6182 Zinc Anode Kit

A zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector.

YSI 6425 Antifouling Optical Chlorophyll Probe
 

6425 Anti-fouling Optical Chlorophyll Sensor (6-Series)

Copper-alloy anti-fouling optical chlorophyll sensor used with 6-Series sondes.

YSI Antifouling Optical Blue-green Algae Probe
 

6431 and 6432 Anti-fouling Optical Blue-Green Algae Sensors (6-Series)

Copper-alloy anti-fouling optical blue-green algae sensor used with 6-Series sondes.

YSI 6436 Antifouling Optical Turbidity Probe
 

6436 Anti-fouling Optical Turbidity Sensor (6-Series)

Copper-alloy anti-fouling optical turbidity sensor used with 6-Series sondes.

YSI ROX Optical Dissolved Oxygen Probe - Copper Antifouling
 

6450 Anti-fouling ROX ® Optical Dissolved Oxygen Sensor (6-Series)

Copper-alloy anti-fouling optical dissolved oxygen sensor used with 6-Series sondes.

6560 Conductivity and Temperature Sensor
 

6560 Conductivity/Temperature Probe

Stable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements.

YSI Rapid Pulse Dissolved Oxygen Sensor
 

6562 Rapid Pulse Dissolved Oxygen Sensor

Obtain unprecedented accuracy and reliability with the YSI 6562 Rapid Pulse™ Dissolved Oxygen Sensor.

6570 Maintenance Kit
 

6570 Sonde Maintenance Kit

Basic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS.

6601 Flow Cell
 

6601 Flow Cell

The 6601 flow cell simply screws onto the bottom of the calibration/transport cup of a 6600 sonde to turn it into a convenient flow cell.

6624 Chlorophyll/Rodamine optical sensor wiper kit.
 

6624 Wiper Kit for Chlorophyll and Rhodamine Sensors

Replacement wipers for 6-series 6025 Chlorophyll probe or 6130 Rhodamine WT probe.

6625 optical wiper kit
 

6625 Wiper Kit for Optical DO, BGA, Turbidity Sensors

Replacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe.


 

6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity Sensors

Replacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher.

6630 Wiper/Brush Kit for 6600EDS
 

6630 Wiper/Brush Kit for 6600EDS

Replacement wiper/brush for 6600EDS sonde.

YSI chloride, ammonium, and nitrate sensors
 

6882, 6883, 6884 Nutrient Ion-Selective-Electrode Sensors (6-Series)

Measure Nutrient Data with Nitrate, Ammonium, and Chloride with Ion Selective Electrodes

6-Series Hard Case
 

6930 Rugged Carrying Case

A hard-sided carrying case ideal for all 6-Series sondes and systems.

Apply C-Spray to Conductivity-Temperature electrodes
 

Anti-fouling C-Spray Protective Probe Solution

C-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments.

Roll of anti-fouling copper tape for YSI sensors and sondes
 

Anti-fouling Copper Tape

Copper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths.

Anti-fouling Port Plug for YSI pH Sensors
 

Anti-fouling Sensor Port Plugs

Copper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection.

Antifouling Screen for Conductivity-Temperature (CT) Sensor
 

Anti-fouling Sensor Screen

Copper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes.

Copper Antifouling Sonde Guard for YSI 600OMS Sonde
 

Anti-fouling Sonde Guards

Copper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes.

YSI Conductivity Solitions
 

Conductivity Calibration Solutions

NIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum
accuracy.

YSI pH Probe (Guarded Glass Bulb) and Flat-glass pH Probe
 

pH Sensors (6-Series)

Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications.

PAR Sensor
 

Photosynthetically Active Radiation (PAR) Sensor

Measure Photosynthetically Active Radiation levels via sensors integrated into a 6600 Sonde.

Turbidity Calibratoin Solutions
 

Turbidity Calibration Solutions

YSI turbidity solutions calibrate your instruments for maximum accuracy. Extremely accurate and stable solutions.

 

 

 

 

<< Back to Products page