600XL and 600XLM
Small Package - Economical Sampling or Logging
Both the YSI 600XL (sampling) and the YSI 600 XLM (logging) are economical solutions in small packages for surface water and groundwater applications. Both easily fit into 2-inch wells and measure a range of fundamental parameters, including oxygen - with the YSI Rapid Pulse™ stirring-independent dissolved oxygen sensor - and level, using a highly-accurate vented sensor.
YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 600XL and 600XLM products and accessories.
Have a question about your YSI 600XL and 600XLM? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI 600XL and 600XLM.
The YSI 600XL and YSI 600XLM compact sondes measure eleven parameters simultaneously:
Connect with Data Collection Platforms
Either sonde can easily connect to the YSI 6200 DAS (Data Acquisition System), YSI EcoNet™ or your own data collection platform, via SDI-12 for remote and real-time data acquisition applications.
Economical Logging System
The YSI 600XLM is an economical logging system for long-term, in situ monitoring and profiling. It will log all parameters at programmable intervals and store 150,000 readings. At one-hour intervals, the instrument will log data for about 75 days utilizing its own power source. The 600XL can also be utilized in the same manner with user-supplied external power.
You can rely on the accuracy and reliability of YSI's sensor technology - the performance of select sensors on the 600XL and 600XLM have been ETV Verified.*
| Medium | Fresh, sea or polluted water | |
| Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Dimensions - 600XL |
Diameter Length Weight |
1.65 in, 4.9 cm 16 in, 40.6 cm 1.3 lbs, 0.59 kg |
| Dimensions - 600XLM |
Diameter Length Weight |
1.65 in, 4.9 cm 21.3 in, 54.1 cm 1.5 lbs, 0.69 kg |
| Power | External Internal (600XLM only) |
12 V DC 4 AA-size alkaline batteries |
| Certifications |
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
|
| Range | Resolution | Accuracy | ||
| Dissolved Oxygen % Saturation 6562 Rapid Pulse™ Sensor* |
0 to 500% | 0.1% | 0 to 200%: ±2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of reading |
|
| Dissolved Oxygen mg/L 6562 Rapid Pulse™ Sensor* |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or 2% of reading, whichever is greater; 20 to 50 mg/L: ±6% of reading |
|
| Conductivity• 6560 Sensor* |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature 6560 Sensor* |
-5 to +50°C | 0.01°C | ±0.15°C | |
| pH 6561 Sensor* |
0 to 14 units | 0.01 unit | ±0.2 unit | |
| ORP | -999 to +999 mV | 0.1 mV | ±20 mV | |
| Depth | Medium Shallow Vented Level |
0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
|
• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). *Sensors with listed with ETV logo were submitted to the ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at |
||||
6-Series Sonde Quick Start Guide
6-Series Multiparameter Water Quality Sondes User Manual
6-Series Sonde Calibration, Maintenance & Troubleshooting Tips
Sonde Connector & Cable Field Reconditioning Procedure
Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills
YSI 600XL and 600XLM Sonde Specifications
Groundwater Applications & Capabilities
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
Desalination Plants: YSI Instruments Monitor Flow & Water Quality at Multiple Stages
YSI Equipment Monitors Ground Water Remediation Project
Lower Colorado River Authority data delivers on-the-spot forecasts and 80-year projections
Monitoring Network Protects International Aquaculture Investment Zones
Español - Red de monitoreo protege inversions en acuicultura en Chile
Landfill Monitoring and Enhanced Intrinsic Bioremediation with YSI Multiparameter Instruments
Maine Companies Partner to Protect Aquatic Life with YSI Integrated Systems
Recording Level in the Floating Marshes of Terrebonne Parish, Louisiana
NJDEP and GHR Consulting Services Choose YSI Instruments for Groundwater Sampling Contract
Drinking Water Monitoring with YSI Instruments and Systems
Connecting 6-series Sondes to a PC via USB
YSI 6562 Rapid Pulse™ Dissolved Oxygen Probe Membrane Maintenance
General O-Ring Care and Maintenance
Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes
|
|
063019 Sonde Weight, SmallReplacement weight for 600 sondes. |
|
|
|
063020 Sonde Weight, LargeReplacement weight for 600 sondes. |
|
|
|
3059 Flow Cell, Standard 203 mLStandard flow cell. 203 mL. Easily disassembles for complete cleaning. Can be used with the Pro Series single or dual-parameter cables, 556, or 600XL and 600XLM instruments. |
|
|
|
3682 Zobell ORP Calibration SolutionYSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
5775 Standard DO MembranesYSI 5775 standard stretch-style dissolved oxygen membranes. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6035 Reconditioning KitReconditioning kit for 6562 Rapid Pulse dissolved oxygen electrodes. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6562 Rapid Pulse Dissolved Oxygen SensorObtain unprecedented accuracy and reliability with the YSI 6562 Rapid Pulse™ Dissolved Oxygen Sensor. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Anti-fouling Copper TapeCopper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths. |
|
|
|
Anti-fouling Sensor Port PlugsCopper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection. |
|
|
|
Anti-fouling Sensor ScreenCopper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes. |
|
|
|
Anti-fouling Sonde GuardsCopper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
Locking Well CapLocking well cap for 2 or 4 inch wells. |
|
|
|
pH Sensors (6-Series)Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications. |
|