6-Series

Multiparameter Sondes

6600 V2

6600EDS V2

6920 V2

6820 V2

600OMS V2

600XL V2 / 600XLM V2

600XL / 600XLM

600QS

600R

600LS

600DW

6920DW

650MDS

6500 Process Monitor

Anti-Fouling Solutions

6-Series Software

EcoWatch

AQUARIUS Time-Series

Streamline-ENV

All YSI Product Accesories - Sensors, Cables, Calibration Solutions & more...

Most Common

Ammonia/Ammonium

Blue-Green Algae

BOD (Biochemical Oxygen Demand)

Chloride

Chlorophyll

Conductivity

Depth

Dissolved Oxygen

Free Chlorine

Level

Nitrate

ORP / Redox

Photosynthetic Active Radiation (PAR)

pH

Resistivity

Rhodamine

Salinity

Specific Conductance

Temperature

Total Dissolved Solids (TDS)

Turbidity

Photometer Parameters

Professional Series

Handheld Instruments

Professional Plus
Multiparameter

ProODO Optical DO/OBOD

Pro20 Lab/Field DO

 

Classic Handheld Series

556MPS Multiparameter

550A Dissolved Oxygen

85 DO/Conductivity

63 pH/Conductivity

60 pH

52/58 Lab/Field DO

55 Dissolved Oxygen

30 Conductivity

Level Scout

Level Scout Level & Temp

 

Laboratory Series

5000/5100 BOD/DO

3200 Conductivity

3100 Conductivity

 

EcoSense

pH10 - pH Pen

pH100 - pH

ORP15 - ORP Pen

DO200 - DO

EC300 - Conductivity

9300/9500 Photometer

 

Aquaculture Systems

5200

YSI Systems

CastAway CTD

Buoys & Floating Platforms

EcoMapper AUV

EcoNet Data-to-Web

Vertical Profiling

Towed Underwater Vehicles

Underway Sampling System

Systems Integration

Other YSI Products

SonTek Acoustic Doppler Systems for water velocity

AMJ Environmental Custom Services

Design Analysis Associates WaterLog Series

YSI Life Sciences

Aquaculture

Coastal

Desalination

Estuary

Drinking Water

Groundwater

Laboratory

Oceans

Raw Water

Source Water

Storm Water

Surface Water

Wastewater

Watersheds / TMDL

Ask a Question

Events & Training

Find a Distributor

Product Service

Resource Library

Software Downloads

Welcome from the CEO

History

News

Career Opportunities

Environmental Stewardship

Sustainability Report

Quality

The YSI Foundation

YSI Incorporated
Find YSI on Facebook Follow YSI on Twitter Watch YSI on YouTube
Login | Register

600XL V2 and 600XLM V2

Product Recycling Product Recycling

Share |

Small Packages - Economical Sampling or Logging


Both the YSI 600XL V2 (sampling) and the YSI 600XLM V2 (logging) offer economical solutions in small packages for surface water and ground water applications. Both models easily fit into 2-inch wells and measure a range of fundamental parameters, including oxygen - with the YSI ROX™ optical dissolved oxygen sensor - and level, using a highly-accurate vented sensor.

YSI 600XLM V2 shown without probe guard.

Find a Distributor

YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 600XL V2 and 600XLM V2 products and accessories.

Find a Distributor

Get Support

Have a question about your YSI 600XL V2 and 600XLM V2? Check out the support page with resources compiled just for you.

Contact Technical Support

Product Service Centers

Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI 600XL V2 and 600XLM V2.

Product Service

 

The YSI 600XL V2 and YSI 600XLM V2 compact sondes measure multiple parameters simultaneously, including:

  • Temperature
  • Conductivity
  • Salinity
  • Specific Conductance
  • Resistivity
  • TDS
  • Depth or Shallow Vented Level
  • pH
  • ORP

Both sondes have one optical port, allowing for measurement of an additional parameter with one of the following optical sensors:

  • ROX™ Optical Dissolved Oxygen
  • Turbidity
  • Chlorophyll
  • Blue-Green Algae (freshwater or marine)
  • Rhodamine

Each optical sensor has an integrated anti-fouling wiper which prolongs deployment times (thus reducing operating costs) and improves the quality of data.

Economical Logging and Spot Sampling System

The YSI 600XLM V2 is an economical logging system for long-term, in situ monitoring, profiling, and spot sampling. It will log all parameters at programmable intervals and store 150,000 readings. At one-hour intervals, the instrument will log data for about 75 days utilizing its own power source. The 600XL V2 can also be used in the same manner with user-supplied external power.

  • Either sonde fits down 2" wells (1.65"    OD)
  • Optical sensor port provides a multipurpose platform
  • Field-replaceable sensors for quicker maintenance
  • Easily connects to data collection platforms
  • Anti-fouling wipers on optical sensors extend deployment times
  • Compatible with YSI 650 Multiparameter Display System
  • Flow cell available for pump-through applications
  • Horizontal measurements in very shallow waters

Connect with Data Collection Platforms

Either sonde can easily connect to the YSI 650 handheld logger/display, YSI 6200 DAS (Data Acquisition System), web-enabled YSI EcoNet® or your own data collection platform, via SDI-12, for remote and real-time monitoring applications.

 


 

Available Sensors

  • Temperature
  • conductivity
  • pH
  • ORP
  • optional depth
    • medium,
    • shallow or
    • shallow vented
  • and one optical sensor:
    • dissolved oxygen*
    • turbidity
    • chlorophyll
    • rhodamine,
    • or blue-green algae
* Note: Rapid Pulse™ polarographic-style DO sensor is not available on the V2 sondes. Please refer to the 600XL or 600XLM sondes.

 

Medium Fresh, sea or polluted water
Temperature Operating
Storage

-5 to +50°C
-40 to +60°C sonde and sensors except pH, pH/ORP
-10 to +60°C for pH and pH/ORP sensors

Maximum Depth
0 to 200 ft (61 m) for sonde
Material PVC, Stainless Steel
600 XL V2
Dimensions
Diameter
Length, no depth
Length, with depth
Weight
1.65 in, 4.19 cm
25.1 in, 63.8 cm
27.1 in, 68.8 cm
1.96 lbs, 0.87 kg (with depth, no bottom weight)
600 XLM V2
Dimensions
Diameter
Length, no depth
Length, with depth
Weight
1.65 in, 4.19 cm
28.5 in, 72.4 cm
30.5 in, 77.5 cm
2.15 lbs, 1.05 kg (with depth, no bottom weight)
Communications RS-232, SDI-12
Memory 384 kb (150,000 individual parameter readings)
Software EcoWatch®
Power 12 V DC
Approximately 30 days at 20˚C at a 15-minute logging interval with optical DO, temperature, conductivity, pH/ORP, and depth sensors operative
Certifications

CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS
Assembled in the USA

 

Range Resolution Accuracy
ROX™
Optical Dissolved Oxygen•
% Saturation
0 to 500% 0.1% 0 to 200%: ±1% of reading or 1% air saturation, whichever is greater;
200 to 500%: ±15% of reading
ROX™
Optical Dissolved Oxygen•
mg/L
0 to 50 mg/L 0.01 mg/L 0 to 20 mg/L: ± 0.1 mg/L or 1% of reading, whichever is greater;
20 to 50 mg/L: ±15% of reading
Conductivity••
6560 Sensor*
0 to 100 mS/cm 0.001 to 0.1 mS/cm
(range dependent)
±0.5% of reading + 0.001 mS/cm
Salinity 0 to 70 ppt 0.01 ppt ±1% of reading or 0.1 ppt,
whichever is greater
Temperature
6560 Sensor*
-5 to +50°C 0.01°C ±0.15°C
pH
6561 Sensor*
0 to 14 units 0.01 unit ±0.2 unit
ORP -999 to +999 mV 0.1 mV ±20 mV
Depth
Medium
Shallow
Vented Level
0 to 200 ft, 61 m
0 to 30 ft, 9.1 m
0 to 30 ft, 9.1 m
0.001 ft, 0.001 m
0.001 ft, 0.001 m
0.001 ft, 0.001 m
±0.4 ft, ±0.12 m
±0.06 ft, ±0.02 m
±0.01 ft, 0.003 m
Turbidity•
6136 Sensor*
0 to 1,000 NTU 0.1 NTU ±2% of reading or 0.3 NTU,
whichever is greater**
Rhodamine• 0-200 μg/L 0.1 μg/L ±5% reading or 1 μg/L,
whichever is greater
• Maximum depth rating for all optical probes is 200 feet, 61 m.
•• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided.
These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989).
**In YSI AMCO-AEPA Polymer Standards.

 

Range Detection Limit Resolution Linearity
Blue-Green Algae
Phycocyanin•
~0 to 280,000 cells/mL†
0 to 100 RFU
~220 cells/mL§ 1 cell/mL
0.1 RFU
R2 > 0.9999**
Blue-Green Algae
Phycoerythrin•
~0 to 200,000 cells/mL†
0 to 100 RFU
~450 cells/mL§§ 1 cell/mL
0.1 RFU
R2 > 0.9999***
Chlorophyll•
6025 Sensor*
~0 to 400 μg/L
0 to 100 RFU
~0.1 μg/L§§§ 0.1 μg/L Chl
0.1% RFU
R2 > 0.9999****
Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m).
RFU = Relative Fluorescence Units
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. § Estimated from cultures of Microcystis aeruginosa.
§§ Estimated from cultures Synechococcus sp.
§§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions.
**For serial dilution of Rhodamine WT (0-400 ug/L).
***For serial dilution of Rhodamine WT (0-8 μg/L).
****For serial dilution of Rhodamine WT (0-500 ug/L).
*Sensors with listed with ETV logo were submitted to the ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at 800.897.4151 800.897.4151 for the ETV verification report. Use of ETV name or logo does not imply approval or certification of this product nor does it make any explicit or implied warranties or guarantees as to product performance.

063019 600 sonde weight
 

063019 Sonde Weight, Small

Replacement weight for 600 sondes.


 

063020 Sonde Weight, Large

Replacement weight for 600 sondes.

YSI 3059 Flow Cell Shown on Side Unassembled
 

3059 Flow Cell, Standard 203 mL

Standard flow cell. 203 mL. Easily disassembles for complete cleaning. Can be used with the Pro Series single or dual-parameter cables, 556, or 600XL and 600XLM instruments.

YSI 3682 Zobell ORP Calibration Solution
 

3682 Zobell ORP Calibration Solution

YSI 3682 Zobell solution is used for calibrating ORP/Redox on several YSI instruments.

YSI pH 4, 7 and 10 buffers
 

3824 Assorted pH Buffers Case

Various pH buffers for pH probe calibration.

YSI Confidence Solution to Check pH, ORP, Conductivity
 

5580 Confidence Solution®

Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®.

YSI 6-series field cable
 

6-Series Field Cables

Rugged cables designed for field use with 6-series sondes.

6025 Chlorophyll Sensor
 

6025 Chlorophyll Sensor (6-Series)

Determine phytoplankton concentrations by detecting the flourescence from chlorophyll in situ.

Indoor-use adapter cable
 

6067B Adapter Cables

YSI 6-series sonde to RS-232 adapter. Indoor-use only.

Field cable to RS-232 adapter.
 

6095B Adapter Cable

YSI 6-series field cable to RS-232 adapter.

PC Interface cable for 650MDS.
 

6112 PC Interface Cable for 650MDS

MS-8 to pc serial port connector for 650MDS.

6130 Rhodamine Sensor
 

6130 Rhodamine Sensor (6-Series)

Detect accurate, in situ trace dye levels with the 6130 Rhodamine Sensor.

Blue-Green Algae Probe
 

6131 and 6132 Blue-Green Algae Sensors (6-Series)

Measure in situ blue-green algae levels in salt- or fresh-water with YSI 6131 and 6132 optical blue-green algae sensors.

6136 Optical Turbidity Sensor
 

6136 Turbidity Sensor (6-Series)

Collect accurate, in situ measurement of turbidity in fresh, brackish, and sea water.

Optical probe wiper pad kit.
 

6144 Wiper Pads for Optical Sensors

Wiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes.

YSI ROX Dissolved Oxygen Probe
 

6150 ROX ® Optical Dissolved Oxygen Sensor (6-Series)

Rugged and reliable optical dissolved oxygen sensor used with 6-Series sondes.

New 6155 membrane
 

6155 Membrane Kit for ROX Optical DO Sensor

Replacement membrane kit for 6150 ROX optical dissolved oxygen sensor (6-series sondes).

Zinc anode on 600 sonde.
 

6182 Zinc Anode Kit

A zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector.

YSI 6425 Antifouling Optical Chlorophyll Probe
 

6425 Anti-fouling Optical Chlorophyll Sensor (6-Series)

Copper-alloy anti-fouling optical chlorophyll sensor used with 6-Series sondes.

YSI Antifouling Optical Blue-green Algae Probe
 

6431 and 6432 Anti-fouling Optical Blue-Green Algae Sensors (6-Series)

Copper-alloy anti-fouling optical blue-green algae sensor used with 6-Series sondes.

YSI 6436 Antifouling Optical Turbidity Probe
 

6436 Anti-fouling Optical Turbidity Sensor (6-Series)

Copper-alloy anti-fouling optical turbidity sensor used with 6-Series sondes.

YSI ROX Optical Dissolved Oxygen Probe - Copper Antifouling
 

6450 Anti-fouling ROX ® Optical Dissolved Oxygen Sensor (6-Series)

Copper-alloy anti-fouling optical dissolved oxygen sensor used with 6-Series sondes.

6560 Conductivity and Temperature Sensor
 

6560 Conductivity/Temperature Probe

Stable multi-probe measures conductivity and temperature levels and calculates salinity values.  Thermistor readings are used to temperature-correct other parameter measurements.

6570 Maintenance Kit
 

6570 Sonde Maintenance Kit

Basic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS.

6624 Chlorophyll/Rodamine optical sensor wiper kit.
 

6624 Wiper Kit for Chlorophyll and Rhodamine Sensors

Replacement wipers for 6-series 6025 Chlorophyll probe or 6130 Rhodamine WT probe.

6625 optical wiper kit
 

6625 Wiper Kit for Optical DO, BGA, Turbidity Sensors

Replacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe.


 

6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity Sensors

Replacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher.

6-Series Hard Case
 

6930 Rugged Carrying Case

A hard-sided carrying case ideal for all 6-Series sondes and systems.

Apply C-Spray to Conductivity-Temperature electrodes
 

Anti-fouling C-Spray Protective Probe Solution

C-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments.

Roll of anti-fouling copper tape for YSI sensors and sondes
 

Anti-fouling Copper Tape

Copper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths.

Anti-fouling Port Plug for YSI pH Sensors
 

Anti-fouling Sensor Port Plugs

Copper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection.

Antifouling Screen for Conductivity-Temperature (CT) Sensor
 

Anti-fouling Sensor Screen

Copper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes.

Copper Antifouling Sonde Guard for YSI 600OMS Sonde
 

Anti-fouling Sonde Guards

Copper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes.

YSI Conductivity Solitions
 

Conductivity Calibration Solutions

NIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum
accuracy.

Locking Well Cap
 

Locking Well Cap

Locking well cap for 2 or 4 inch wells.

YSI pH Probe (Guarded Glass Bulb) and Flat-glass pH Probe
 

pH Sensors (6-Series)

Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications.

Turbidity Calibratoin Solutions
 

Turbidity Calibration Solutions

YSI turbidity solutions calibrate your instruments for maximum accuracy.

 

Form Object

 

 

 