600OMS V2
Single-Parameter, Low-Cost Optical Monitoring System
Measure optical dissolved oxygen, chlorophyll, blue-green algae, rhodamine, or turbidity in combination with temperature, conductivity and depth. Designed for use in fresh, sea or polluted waters, the 600OMS V2 data sonde utilizes the field-proven YSI sensors and incorporates innovations in water quality sensor configuration such as a conductivity and temperature module that fits into the sonde body.

YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 600OMS V2 products and accessories.
Have a question about your YSI 600OMS V2? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you'll find authorized service centers and instructions on how to send in your YSI 600OMS V2.
Designed for use in fresh, sea or polluted waters, the 600OMS V2 utilizes the field-proven YSI sensors and incorporates innovations in sensor configuration such as a conductivity and temperature module that fits into the sonde body.
Parameters available for the 600OMS V2 include:
The 600OMS V2 is available with or without internal power. Its small size is perfect for applications such as turbidity or oxygen monitoring.
Features:
Extend deployment intervals by 3 times or more with Anti-Fouling Kits
You can rely on the accuracy and reliability of YSI's sensor technology-the performance of select sensors on the 600OMS V2 have been ETV Verified.*
Related Products |
|||
|
EXO1 Water Quality Sonde |
EXO2 Water Quality Sonde |
EXO Handheld |
Multiparameter Sondes |
|
6600V2 |
6920 V2 |
6820 V2 |
600XL V2 and 600XLM V2 |
|
600LS |
EcoNet |
|
YSI 600OMS Sonde Specifications
| Medium | Fresh, sea or polluted water | |
| Temperature | Operating Storage |
-5 to +50°C -10 to +60°C |
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Dimensions | Diameter Length Weight Weight with Batteries |
1.65 in, 4.2 cm 21.3 in, 54.1 cm 1.3 lbs, 0.6 kg 1.4 lbs, 0.7 kg |
| Power |
External |
12 V DC 4 AA Alkaline cells, 25 to 30 days at 15 minute sampling interval at 25°C |
| Certifications |
CE, EU Battery Compliance, FCC, IP-67, WEEE, and MCERTS |
|
YSI 600OMS Sensor Specifications
| Range | Resolution | Accuracy | ||
| ROX™ Optical Dissolved Oxygen• % Saturation |
0 to 500% | 0.1% | 0 to 200%: ±1% of reading or 1% air saturation, whichever is greater; 200 to 500%: ±15% of reading |
|
| ROX™ Optical Dissolved Oxygen• mg/L |
0 to 50 mg/L | 0.01 mg/L | 0 to 20 mg/L: ± 0.1 mg/L or 1% of reading, whichever is greater; 20 to 50 mg/L: ±15% of reading |
|
| Conductivity•• | 0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature | -5 to +50°C | 0.01°C | ±0.15°C | |
| Depth | Medium Shallow Vented Level |
0 to 200 ft, 61 m 0 to 30 ft, 9.1 m 0 to 30 ft, 9.1 m |
0.001 ft, 0.001 m 0.001 ft, 0.001 m 0.001 ft, 0.001 m |
±0.4 ft, ±0.12 m ±0.06 ft, ±0.02 m ±0.01 ft, 0.003 m |
| Turbidity• 6136 Sensor* |
0 to 1,000 NTU | 0.1 NTU | ±2% of reading or 0.3 NTU, whichever is greater** |
|
| Rhodamine• | 0-200 μg/L | 0.1 μg/L | ±5% reading or 1 μg/L, whichever is greater |
|
| • Maximum depth rating for optical probes is 200 feet, 61 m. Anti-fouling optical probes have depth rating of 200 m. •• Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). |
**In YSI AMCO-AEPA Polymer Standards. | |||
| Range | Detection Limit | Resolution | Linearity | |
| Blue-Green Algae Phycocyanin• |
~0 to 280,000 cells/mL† 0 to 100 RFU |
~220 cells/mL§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999** |
| Blue-Green Algae Phycoerythrin• |
~0 to 200,000 cells/mL† 0 to 100 RFU |
~450 cells/mL§§ | 1 cell/mL 0.1 RFU |
R2 > 0.9999*** |
| Chlorophyll• 6025 Sensor* |
~0 to 400 μg/L 0 to 100 RFU |
~0.1 μg/L§§§ | 0.1 μg/L Chl 0.1% RFU |
R2 > 0.9999**** |
| • Maximum depth rating for all optical probes is 200 feet, 61 m. Also available in a Deep Depth option (0 to 200 m). RFU = Relative Fluorescence Units |
† Explanation of Ranges can be found in the ‘Principles of Operation’ section of the 6-Series Manual, Rev D. | § Estimated from cultures of Microcystis aeruginosa. §§ Estimated from cultures Synechococcus sp. §§§ Determined from cultures of Isochrysis sp. and chlorophyll a concentration determined via extractions. |
**For serial dilution of Rhodamine WT (0-400 ug/L). ***For serial dilution of Rhodamine WT (0-8 μg/L). ****For serial dilution of Rhodamine WT (0-500 ug/L). |
|
| *Sensors with listed with ETV logo were submitted to the ETV program on the YSI 6600EDS. Information on performance characteristics of YSI water quality sensors can be found at www.epa.gov/etv, or call YSI at |
||||
Ordering Information
| Item # | Description |
| 600-01 | 600OMS V2 sonde, conductivity, temperature, optical port |
| 600-02 | 600OMS V2 sonde, conductivity, temperature, optical port, internal batteries |
| 600-03 | 600OMS V2 sonde, conductivity, temperature, optical port, shallow depth |
| 600-04 | 600OMS V2 sonde, conductivity, temperature, optical port, shallow depth, internal batteries |
| 600-05 | 600OMS V2 sonde, conductivity, temperature, optical port, medium depth |
| 600-06 | 600OMS V2 sonde, conductivity, temperature, optical port, medium depth, internal batteries |
| 600-07 | 600OMS V2 sonde, conductivity, temperature, optical port, shallow vented depth |
| 600-08 | 600OMS V2 sonde, conductivity, temperature, optical port, shallow vented depth, internal batteries |
6-Series Sonde Quick Start Guide
6-Series Multiparameter Water Quality Sondes User Manual
6-Series Sonde Calibration, Maintenance & Troubleshooting Tips
Sonde Connector & Cable Field Reconditioning Procedure
Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills
YSI 6131 and 6132 Blue-Green Algae Sensors
YSI ROX Optical Dissolved Oxygen Sensor
600OMS V2 Optical Monitoring System Specifications
Wastewater - Water Quality Capabilities & Solutions
Monitoring Systems that Deliver Better Results from YSI Integrated Systems
Dissolved Oxygen Case Studies & Solutions
Source Water Monitoring - Applications, Capabilities & Solutions
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
Japanese - YSI 6シリーズ 多項目水質モニター
6-Series Anti-Fouling Kits Prevent Biofouling, Extend Long-Term Deployments
Students Monitor Harlem River Water Quality and Air Quality, Seek Solutions
YSI 600OMS used to Protect Lake Oconee, Georgia Water Quality
Connecting 6-series Sondes to a PC via USB
Deployment and Data Quality Assurance Tips
General O-Ring Care and Maintenance
Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes
YSI Instruments EPA Compliance Guide
YSI's Mike Lizotte and Tom Moeggenberg present a free, informative webinar about making accurate turbidity measurements in marine and fresh waters.
Topics include:
• YSI Turbidity Sensor Technology
• Choosing the right calibration standard
• Turbidity probe calibration procedures, and the use of offsets
• Best practices for long-term measurements
• Anti-fouling techniques
• Post-calibration techniques for sampling and long-term studies
• Q&A
Who should listen:
• Those using submersible field sensors for water quality sampling and monitoring
• Those measuring turbidity for storm water, construction run-off, flood events, TMDLs or other water quality concerns
|
|
063018 Sonde Weight, SmallReplacement weight for 600 sondes. |
|
|
|
063019 Sonde Weight, MediumReplacement weight for 600 sondes. |
|
|
|
063020 Sonde Weight, LargeReplacement weight for 600 sondes. |
|
|
|
202350 PACS-1 Power and Communication SystemGet Water Data with Bluetooth® Wireless Technology and Solar Power. The YSI Power and Communication System (PACS) supplies continuous power to submerged water instrumentation and enables wireless communication with the instrumentation. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6025 Chlorophyll Sensor (6-Series)Determine phytoplankton concentrations by detecting the fluorescence from chlorophyll in situ. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6130 Rhodamine Sensor (6-Series)Detect accurate, in situ trace dye levels with the 6130 Rhodamine Sensor. |
|
|
|
6131 and 6132 Blue-Green Algae Sensors (6-Series)Measure in situ blue-green algae levels in salt- or fresh-water with YSI 6131 and 6132 optical blue-green algae sensors. |
|
|
|
6136 Turbidity Sensor (6-Series)Collect accurate, in situ measurement of turbidity in fresh, brackish, and sea water. |
|
|
|
6144 Wiper Pads for Optical SensorsWiper pad kit for 6-series optical DO, BGA, turbidity, chlorophyll, and rhodamine probes. |
|
|
|
6150 ROX ® Optical Dissolved Oxygen Sensor (6-Series)Rugged and reliable optical dissolved oxygen sensor used with 6-Series water quality sondes. |
|
|
|
6155 Membrane Kit for ROX Optical DO SensorReplacement membrane kit for 6150 ROX optical dissolved oxygen sensor (6-series sondes). |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6425 Anti-fouling Optical Chlorophyll Sensor (6-Series)Copper-alloy anti-fouling optical chlorophyll sensor used with 6-Series sondes. |
|
|
|
6431 and 6432 Anti-fouling Optical Blue-Green Algae Sensors (6-Series)Copper-alloy anti-fouling optical blue-green algae sensor used with 6-Series sondes. |
|
|
|
6436 Anti-fouling Optical Turbidity Sensor (6-Series)Copper-alloy anti-fouling optical turbidity sensor used with 6-Series sondes. |
|
|
|
6450 Anti-fouling ROX ® Optical Dissolved Oxygen Sensor (6-Series)Copper-alloy anti-fouling optical dissolved oxygen sensor used with 6-Series sondes. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6624 Wiper Kit for Chlorophyll and Rhodamine SensorsReplacement wipers for 6-series 6025 Chlorophyll probe or 6130 Rhodamine WT probe. |
|
|
|
6625 Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. |
|
|
|
6625AF Anti-fouling Wiper Kit for Optical DO, BGA, Turbidity SensorsReplacement wiper kit (copper) for the 6150 optical dissolved oxygen probe; 6131 and 6132 blue-green algae probes; or 6136 turbidity probe. Use with firmware version 3.06 or higher. |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Anti-fouling Copper TapeCopper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths. |
|
|
|
Anti-fouling Sensor Port PlugsCopper-alloy port plugs protect unused sensor ports on YSI 6-Series sondes and provide anti-fouling protection. |
|
|
|
Anti-fouling Sensor ScreenCopper-mesh screens block organisms and provide biofouling protection for the 6560 Conductivity-Temperature probe and non-wiped pH probes. |
|
|
|
Anti-fouling Sonde GuardsCopper-alloy sonde guards protect water quality sensors and provide biofouling protection for YSI 6-Series Sondes. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
Locking Well CapLocking well cap for 2 or 4 inch wells. |
|
|
|
pH Sensors (6-Series)Simple, accurate pH measurement in sensors designed for minimal maintenance in sampling, profiling, and long-term monitoring applications. |
|
|
|
Sensor Adapter KitExpand your water quality monitoring to include hydrocarbons, oil, or CDOM with the YSI Sensor Adapter and Turner Cyclops-7 submersible sensors. The YSI 202400 Sensor Adapter expands water quality monitoring to include third-party analog output sensors. In addition to monitoring for Temperature, Conductivity, pH, Dissolved Oxygen, Turbidity, Blue-Green Algae, and Chlorophyll, 6-Series sondes can measure hydrocarbons, oil in water, and other parameters from the Turner Cyclops-7® submersible sensor line. |
|
|
|
Turbidity Calibration SolutionsYSI turbidity solutions calibrate your instruments for maximum accuracy. Extremely accurate and stable solutions. |
|