600LS
Precise Level Measurement in a Compact Sonde
Measure level, flow, temperature and conductivity with the compact 600LS sonde. Rugged and waterproof, the YSI 600LS is perfect for tide gauge monitoring, wetlands level applications, ground water, estuaries, rivers, and more.
YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 600LS products and accessories.
Have a question about your YSI 600LS? Check out the support page with resources compiled just for you.
Want to return a product for service? Here you’ll find authorized service centers and instructions on how to send in your YSI 600LS.
Available with and without conductivity, YSI recommends conductivity when used in saline environments for the most accurate level measurements.
Parameters available on the 600LS:
Adding conductivity provides additional parameters including Resistivity, Salinity, Specific Conductance and Total Dissolved Solids (TDS).
Features:
YSI 600LS Sonde Specifications
| Medium | Fresh, sea or polluted water | |
| Temperature | -5 to +50°C |
|
| Communications | RS-232, SDI-12 | |
| Software | EcoWatch® | |
| Dimensions | Diameter Length, no batteries Weight |
1.65 in, 4.2 cm 15 in, 38 cm 1.10 lbs, 0.5 kg |
| Power | External Internal (optional) |
12 V DC 4 AA-size alkaline batteries |
YSI 600LS Sensor Specifications
| Range | Resolution | Accuracy | ||
| Conductivity• |
0 to 100 mS/cm | 0.001 to 0.1 mS/cm (range dependent) |
±0.5% of reading + 0.001 mS/cm | |
| Salinity | 0 to 70 ppt | 0.01 ppt | ±1% of reading or 0.1 ppt, whichever is greater |
|
| Temperature |
-5 to +50°C | 0.01°C | ±0.15°C | |
| Depth | Vented Level | 0 to 30 ft, 9.1 m | 0.001 ft, 0.001 m | ±0.01 ft, 0.003 m |
| • Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided. These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989). |
||||
Ordering Information
| Item # |
Description |
| 600LS-10 | Temperature, Shallow vented level |
| 600LS-11 | Temperature, Shallow vented level, Battery option |
| 600LS-12 | Temperature, Conductivity, Shallow vented level |
| 600LS-13 | Temperature, Conductivity, Shallow vented level, Battery option |
| Cables | |
| 6195 | 10 ft vented detachable cable |
| 6191 | 25 ft vented detachable cable |
| 6192 | 50 ft vented detachable cable (Shallow vented level maximum depth is 30 feet.) |
6-Series Sonde Quick Start Guide
6-Series Multiparameter Water Quality Sondes User Manual
6-Series Sonde Calibration, Maintenance & Troubleshooting Tips
Sonde Connector & Cable Field Reconditioning Procedure
Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills
YSI 600LS Level Sonde Specifications
Groundwater Applications & Capabilities
Source Water Monitoring - Applications, Capabilities & Solutions
6-Series Multiparameter Water Quality Sondes
Français - Sondes multiparamètres série 6 surveillance des eaux
Deutsch - 6-Serie Multiparameter Wasserqualitäts-Messsonden
Connecting 6-series Sondes to a PC via USB
Deployment and Data Quality Assurance Tips
General O-Ring Care and Maintenance
Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes
|
|
063019 Sonde Weight, SmallReplacement weight for 600 sondes. |
|
|
|
063020 Sonde Weight, LargeReplacement weight for 600 sondes. |
|
|
|
3824 Assorted pH Buffers CaseVarious pH buffers for pH probe calibration. |
|
|
|
5580 Confidence Solution®Never worry about the accuracy of your pH, ORP, or conductivity data again! Ensure probe performance with the 5580 Confidence Solution®. |
|
|
|
5775 Standard DO MembranesYSI 5775 standard stretch-style dissolved oxygen membranes. |
|
|
|
6-Series Field CablesRugged cables designed for field use with 6-series sondes. |
|
|
|
6067B Adapter CablesYSI 6-series sonde to RS-232 adapter. Indoor-use only. |
|
|
|
6095B Adapter CableYSI 6-series field cable to RS-232 adapter. |
|
|
|
6112 PC Interface Cable for 650MDSMS-8 to pc serial port connector for 650MDS. |
|
|
|
6182 Zinc Anode KitA zinc "sacrificial" anode minimizes corrosion damage to metallic parts of the sonde, namely its stainless steel connector. |
|
|
|
6560 Conductivity/Temperature ProbeStable multi-probe measures conductivity and temperature levels and calculates salinity values. Thermistor readings are used to temperature-correct other parameter measurements. |
|
|
|
6570 Sonde Maintenance KitBasic maintenance kit for all YSI 6-Series sondes except the 600R and 600QS. |
|
|
|
6930 Rugged Carrying CaseA hard-sided carrying case ideal for all 6-Series sondes and systems. |
|
|
|
Anti-fouling C-Spray Protective Probe SolutionC-Spray is a unique nanopolymer coating that inhibits biofouling attachment on the YSI 6560 Conductivity/Temperature Probe and other sensors and water quality instruments. |
|
|
|
Anti-fouling Copper TapeCopper tape for YSI water quality sondes and sensors provides biofouling protection and extends deployment lengths. |
|
|
|
Conductivity Calibration SolutionsNIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum |
|
|
|
Locking Well CapLocking well cap for 2 or 4 inch wells. |
|