Multiparameter Sondes

EXO1

EXO2

6600 V2

6920 V2

600OMS V2

Legacy Sondes

All Legacy Sondes

CTD

CastAway CTD

Process Monitors

IQ SensorNet 2020 XT

IQ SensorNet 182

P 700 Orthophosphate

Aquaculture Systems

5200A Multiparameter

5400 MultiDO

5500 MultiDO Optical

AquaViewer App

Professional Series

Handheld Instruments

Pro Plus Multiparameter

ProODO Optical DO/OBOD

Pro20 Lab/Field DO

Pro1020 Field DO/pH/ORP

Pro1030 Field pH/ORP/Cond

Pro2030 Field DO/Cond

Pro30 Field Cond

Classic Handheld Series

556MPS Multiparameter

550A Dissolved Oxygen

63 pH/Conductivity

60 pH

58 Lab/Field DO

55 Dissolved Oxygen

Colorimeters

900 Chlorine

910 COD

pHotoFlex Colorimeters

Laboratory Series

pH1200

5000/5100 BOD/DO

3200 Conductivity

3100 Conductivity

MultiLab 4010-1

MultiLab 4010-2

MultiLab 4010-3

TruLab 1110

TruLab 1310 and 1310P

TruLab 1320 and 1320P

EcoSense

pH10A - pH Pen

pH100A - pH

ORP15A - ORP Pen

DO200A - DO

EC30A - Conductivity Pen

EC300A - Conductivity

9300/9500 Photometer

All YSI Accessories

Sensors, Cables, Calibration Solutions & more...

YSI Systems

Buoys & Floating Platforms

EcoMapper AUV

EcoNet Data-to-Web

Vertical Profiling

Towed Underwater Vehicles

Underway Sampling System

Other YSI Products

SonTek Acoustic Doppler Systems for water velocity

YSI Systems

DAA WaterLog

YSI Life Sciences

Ammonia/Ammonium

Blue-Green Algae

BOD (Biochemical Oxygen Demand)

CDOM

Chloride

Chlorophyll

Conductivity

Depth

Dissolved Oxygen

Free Chlorine

Level

Nitrate

Oil / Hydrocarbon

ORP / Redox

Photosynthetic Active Radiation (PAR)

pH

Resistivity

Rhodamine

Salinity

Specific Conductance

Temperature

Total Dissolved Solids (TDS)

Turbidity

Colorimeter Parameters

Photometer Parameters

Aquaculture

Coastal

Desalination

Estuary

Drinking Water

Groundwater

Hydraulic Fracturing

Laboratory

Oceans

Raw Water

Source Water

Storm Water

Surface Water

Wastewater

Watersheds / TMDL

Ask a Question

Events & Training

Find a Distributor

Product Service

Resource Library

Software Downloads

Welcome from the GM

History

News

Career Opportunities

Environmental Stewardship

Sustainability

Quality

Xylem Watermark

YSI - A Xylem Brand
Find YSI on Facebook Follow YSI on Twitter Watch YSI on YouTube
Login | Register
Loading

3200

Product Recycling Recycling

Pin It

Laboratory Conductivity, Resistivity, Salinity, TDS

 

The YSI is an innovative instrument that offers unmatched accuracy for ultrapure water analysis, multipoint calibration, and a high/low alarm for process applications.

YSI 3200 Lab Conductivity Meter
Send me a Quote!

Find a Distributor

YSI has Authorized Distributors all over the globe. View a map and find your closest contact for YSI 3200 products and accessories.

Find a Distributor

Get Support

Have a question about your YSI 3200? Check out the support page with resources compiled just for you.

Contact Technical Support

Product Service Centers

Want to return a product for service? Here you'll find authorized service centers and instructions on how to send in your YSI 3200.

Product Service

 

Measurements include conductivity, resistivity, salinity, total dissolved solids and temperature.

With YSI's exclusive accurate Resistance Ratio TechnologyTM (RRT), the 3200 continually compares the resistance of the sample to a calibrated resistor in the circuit.

Ensure the most accurate measurements with NIST-traceable conductivity cells with built-in temperature sensors and exceed USP24 specifications.

To ensure even greater accuracy, utilize the YSI conductivity calibration solutions.

Features:

  • Highly accurate Resistance Ratio Technology
  • Multipoint calibration
  • High and low alarms
  • Linear and nonlinear temperature compensation options
  • Data storage and logging

 

 

 

 

YSI 3200 Instrument General Specifications

Alarm Yes
Calibration Multipoint, up to 5 points
Cell Connector 7-pin Mini Din
Cell constant, cm-1 0.001 - 100 cm-1
Cell Information Storage 6 Configurations
Certifications UL, CSA, CE
Clock Yes
Data Storage 100 points
Dimensions Size 9 by 9.5 by 4.4 in (22.9 by 24.1 by 11.2 cm)
Weight 2.6 lbs (1.1 kg)
Display Graphic LCD
Operating Environment 95% relative humidity, non-condensing
Outputs RS-232
Platinizing Capability Included
Power AC, 115V, 220V
Temperature Compensation Method Linear, nonlinear
Reference temperature °C 0 - 100
Temperature. Coefficient 0 - 10%/°C, nonlinear
Water Resistance The Model 5000 and 5100 are designed exclusively for indoor use and are NOT waterproof.
Warranty 2-year instrument

 

YSI 3200 Specifications (Instrument Only)

Conductance
Range Accuracy Resolution Frequency
0 - 0.9999 µS ± 0.30% full scale 0.0001 µS 40 Hz
0.950 - 9.999 µS ± 0.20% full scale 0.001 µS 80 Hz
9.50 µS - 99.99 µS ± 0.10% full scale 0.01 µS 290 Hz
95.0 - 999.9 µS ± 0.10% full scale 0.1 µS 1010 Hz
950 - 9999 µS ± 0.10% full scale 1 µS 1010 Hz
9.50 - 99.99 mS ± 0.10% full scale 0.01 mS 1010 Hz
95.0 - 999.9 mS ± 0.30% full scale 0.1 mS 1460 Hz
0.95 - 3.00 S ± 1.0% full scale 0.01 S 1460 Hz

Resistance
Range Accuracy Resolution Frequency
0 - 9.999 Ω ± 0.2% full scale 0.001Ω 1460 Hz
0 - 99.99 Ω ± 0.1% full scale 0.01 Ω 1460 Hz
0 - 999.9 Ω ± 0.1% full scale 0.1 Ω 1010 Hz
0 - 9.999 kΩ ± 0.1% full scale 0.001 kΩ 1010 Hz
0 - 99.99 kΩ ± 0.1% full scale 0.01 kΩ 1010 Hz
100.0 - 999.9 kΩ ± 0.2% full scale 0.1 kΩ 290 Hz
1.00 - 9.99 MΩ ± 0.5% full scale 0.01 MΩ 80 Hz
10.0 - 29.9 MΩ ± 1% full scale 0.1 MΩ 40 Hz

 

Range Accuracy Resolution
Salinity 0-80 ppt (NaCl) ±.1 ppt 0.1 ppt
TDS 0-19,999 mg/L 0.50% 1 mg/L
Temperature -5 - 100°C ±0.1°C 0.01°C

 


Conductivity Cell General Measurement Ranges

Conductivity Cell General Specifications

3200 Series Cells with built-in temperature sensors

Model cgs Cell Type
S.I. Cell Constant Cell Constant Material Overall Length (mm) Max O.D. (mm) Chamber I.D. (mm) Chamber Depth (mm) Volume
A 3252 dip 1.0/cm 100/m ABS plastic 146 13 10 20
B 3253 dip, micro 1.0/cm 100/m Pyrex 7740 178 13 10 51
C 3254 fill 1.0/cm 100/m Pyrex 7740 135 19 11 83 5 mL
D 3255 flow 0.1/cm 10/m Pyrex 7740 146 25 21 76 30 mL
E 3256 dip 0.1/cm 10/m Pyrex 7740 159 25 21 52


3400 Series Cells without built-in temeprature sensors*


Model cgs Cell Type S.I. Cell Constant Cell Constant Material Overall Length (mm)
Max O.D. (mm)
Chamber I.D. (mm) Chamber Depth (mm) Volume
F 3401 dip 1.0/cm 100/m Pyrex 7740 191 25 21 76
G 3402 dip 0.1/cm 10/m Pyrex 7740 159 25 21 52
H 3403 dip 1.0/cm 100/m Pyrex 7740 178 13 10 51
I 3417 dip 1.0/cm 100/m ABS plastic 146 13 10 20
I 3418 dip 0.1/cm 10/m ABS plastic 159 13 10 30
J 3440 dip 10/cm 1000/m Pyrex 7740 203 13 2 86
*Requires a YSI 3232 Cell Adaptor for use with YSI 3100 and 3200 Conductivity Instruments. For automatic temperature compensation, use a YSI 3220 on the 3200

YSI Conductivity Cells Shown in Order 3252, 3253, 3254, 3255, 3256
 

3200 Series Conductivity Cells

YSI conductivity cells with built-in temperature sensors.

YSI Conductivity Solitions
 

Conductivity Calibration Solutions

NIST-traceable conductivity solutions to calibrate both field instruments and lab instruments and cells together for maximum
accuracy.

 

 

 

 

<< Back to Products page